HP 6125G HP 6125G & 6125G/XG Blade Switches Layer 2 - LAN Switching Co - Page 16
Field, Description, The Maximum Frame Length
View all HP 6125G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Field Loopback is not set Unknown-speed mode unknown-duplex mode Link speed type is autonegotiation link duplex type is autonegotiation The Maximum Frame Length Broadcast MAX-ratio Unicast MAX-ratio Multicast MAX-ratio Allow jumbo frame to pass PVID Mdi type Port link-type Tagged VLAN ID Untagged VLAN ID Last clearing of counters: Never Peak value of input Peak value of output Last 300 seconds input: 0 packets/sec 0 bytes/sec Last 300 seconds output: 0 packets/sec 0 bytes/sec Input (total): 0 packets, 0 bytes 0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses Input (normal): 0 packets, - bytes 0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses input errors runts Description The loopback testing function is disabled. The port speed is unknown. The duplex mode is unknown. The interface will negotiate a speed with its peer. The interface will negotiate a duplex mode with its peer. Maximum Ethernet frame length allowed on the interface. Broadcast suppression threshold as a percentage of the interface transmission capability. When the threshold is exceeded, the interface drops broadcast packets. Unknown unicast suppression threshold as a percentage of the interface transmission capability. When the threshold is exceeded, the interface drops unknown unicast packets. Multicast suppression threshold as a percentage of the interface transmission capability. When the threshold is exceeded, the interface drops multicast packets. Maximum length of Ethernet frames that are allowed to pass through the interface. Port VLAN ID. Cable type. Link type of the interface, which could be access, trunk, or hybrid. VLANs for which the interface sends packets without removing VLAN tags. VLANs for which the interface sends packets after removing VLAN tags. Time when the reset counters interface command was last used to clear statistics on the interface. Never indicates that the reset counters interface command was never used since the switch was started. Peak value of inbound traffic, in Bps. Peak value of outbound traffic, in Bps. Average rate of input and output traffic in the last 300 seconds, in pps and Bps. Inbound traffic statistics (in packets and bytes) for the interface. All inbound normal and abnormal packets (including unicast, broadcast, and multicast), and pause frames were counted. Inbound traffic statistics (in packets and bytes) for the interface. All inbound normal packets (including unicast, broadcast, and multicast), and pause frames were counted. Inbound packets with errors. Inbound frames shorter than 64 bytes, in correct format, and containing valid CRCs. 8