Dell PowerEdge T300 Hardware Owner's Manual (PDF) - Page 22
E1414 CPU, Thermtrip, Presence, E141C CPU Mismatch, Management Utility. See - power cord
View all Dell PowerEdge T300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Table 1-5. LCD Status Messages (continued) Code Text Causes Corrective Actions E1414 CPU # Thermtrip Specified microprocessor is out of acceptable temperature range and has halted operation. See "Troubleshooting System Cooling Problems" on page 145. If the problem persists, ensure that the microprocessor heat sinks are properly installed (see "Troubleshooting the Microprocessor" on page 161). NOTE: The LCD continues to display this message until the system's power cord is disconnected and reconnected to the AC power source, or the SEL is cleared using either Server Assistant or the BMC Management Utility. See the Dell OpenManage™ Baseboard Management Controller User's Guide for information about these utilities. E1418 CPU # Presence Specified processor is See "Troubleshooting the missing or bad, and the Microprocessor" on system is in an unsupported page 161. configuration. E141C CPU Mismatch Processors are in an unsupported configuration. Ensure that your processors match and conform to the type described in the Microprocessor Technical Specifications outlined in your system's Getting Started Guide. 22 About Your System