Table 1-6., System Messages, Message, Causes, Corrective Actions, Keyboard Controller
View all Dell PowerEdge T300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Table 1-6. System Messages (continued) Message Causes Corrective Actions Keyboard Controller Faulty keyboard failure controller; faulty system board See "Getting Help" on page 175. Keyboard data line failure Keyboard stuck key failure Keyboard cable connector Check the keyboard is loose or improperly connection to the system. If connected, defective the problem persists, try keyboard, or defective another keyboard. keyboard/mouse controller Manufacturing mode System is in detected manufacturing mode. Reboot to take the system out of manufacturing mode. Memory address line Faulty or improperly failure at address, installed memory read value modules. expecting value See "Troubleshooting System Memory" on page 146. Memory double word logic failure at address, read value expecting value Memory odd/even logic failure at address, read value expecting value Memory write/read failure at address, read value expecting value Memory tests terminated by keystroke POST memory test terminated by pressing the spacebar. Information only. About Your System 33