Dell PowerEdge T300 Hardware Owner's Manual (PDF) - Page 27
E201E POST Mem Test, E201F DRAC Config - e2022 post fail
View all Dell PowerEdge T300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
Table 1-5. LCD Status Messages (continued) Code Text Causes Corrective Actions E201C SMI Init System management interrupt (SMI) initialization failure. See "Getting Help" on page 175. E201D Shutdown Test BIOS shutdown test failure. See "Getting Help" on page 175. E201E POST Mem Test BIOS POST memory test failure. See "Troubleshooting System Memory" on page 146. If the problem persists, see "Getting Help" on page 175. E201F DRAC Config Remote Access Controller Check screen for specific (RAC) configuration failure. error messages. Ensure that RAC cables and connectors are properly seated. If problem persists, see your RAC documentation. E2020 CPU Config CPU configuration failure. Check screen for specific error messages. E2021 Memory Population Incorrect memory configuration. Memory population order incorrect. Check screen for specific error messages (see "Troubleshooting System Memory" on page 146). E2022 POST Fail General failure after video. Check screen for specific error messages. E2110 MBE DIMM # & # One of the DIMMs in the See "Troubleshooting set implicated by "# & #" System Memory" on has had a memory multi-bit page 146. error (MBE). About Your System 27