Dell PowerEdge T610 Hardware Owner's Manual - Page 28
Check CPU or, CPU Bus parity - heat
View all Dell PowerEdge T610 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Table 1-1. LCD Status Messages (continued) Code Text Causes Corrective Actions E1414 CPU # temp exceeding range. Check CPU heatsink. Specified processor is out Ensure that the processor of acceptable temperature heat sinks are properly range. installed. See "Troubleshooting the Processor(s)" and "Troubleshooting System Cooling Problems." E1418 CPU # not detected. Check CPU is seated properly. Specified processor is missing or bad, and the system is in an unsupported configuration. Ensure that the specified microprocessor is properly installed. See "Troubleshooting the Processor(s)." E141C Unsupported Processors are in an CPU unsupported configuration. configuration. Check CPU or BIOS revision. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system's Getting Started Guide. E141F CPU # protocol The system BIOS has error. Power reported a processor cycle AC. protocol error. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help." E1420 CPU Bus parity The system BIOS has error. Power reported a processor bus cycle AC. parity error. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help." E1422 CPU # machine check error. Power cycle AC. The system BIOS has Remove AC power to the reported a machine check system for 10 seconds and error. restart the system. If the problem persists, see "Getting Help." 28 About Your System