Dell PowerEdge T610 Hardware Owner's Manual - Page 29
E1618 Predictive, Power Supply - shutting down
View all Dell PowerEdge T610 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Table 1-1. LCD Status Messages (continued) Code Text Causes Corrective Actions E1610 Power Supply # Specified power supply See "Troubleshooting (### W) was removed or is missing Power Supplies." missing. Check from the system. power supply. E1614 Power Supply # Specified power supply (### W) error. has failed. Check power supply. See "Troubleshooting Power Supplies." E1618 Predictive A power supply fan failure, See "Troubleshooting failure on an over-temperature Power Supplies." Power Supply # condition, or a power (### W). Check supply communication PSU. error has caused the predictive warning of an impending power supply failure. E161C Power Supply # Specified power supply is (### W) lost attached to the system, AC power. but it has lost its AC Check PSU input. cables. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supplies." E1620 Power Supply # Specified power supply's Check the AC power (### W) AC AC input is outside of the source for the specified power error. allowable range. power supply. If the Check PSU problem persists, see cables. "Troubleshooting Power Supplies." E1624 Lost power supply redundancy. Check PSU cables. The power supply subsystem is no longer redundant. If the remaining power supply fails, the system will shut down. See "Troubleshooting Power Supplies." About Your System 29