Dell PowerEdge T610 Hardware Owner's Manual - Page 32
SAS cable B - review
View all Dell PowerEdge T610 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Table 1-1. LCD Status Messages (continued) Code Text Causes Corrective Actions E1717 CPU # internal error. Review & clear SEL. The system BIOS has determined that the specified processor has had an internal error. Check the SEL for more information and then clear the SEL. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help." E171F PCIe fatal error on Bus ## Device ## Function ## The system BIOS has Remove and reseat the reported a PCIe fatal error PCIe expansion cards. If on a component that the problem persists, see resides in PCI "Troubleshooting configuration space at bus Expansion Cards." ##, device ##, function ##. E1810 Hard drive ## The specified hard drive fault. Review has experienced a fault. & clear SEL. See "Troubleshooting a Hard Drive." E1812 Hard drive ## The specified hard drive removed. Check has been removed from drive. the system. Information only. E1A14 SAS cable A SAS cable A is missing or Reseat the cable. If the failure. Check bad. problem persists, replace connection. cable. If the problem persists, see "Getting Help." E1A15 SAS cable B SAS cable B is missing or Reseat the cable. If the failure. Check bad. problem persists, replace connection. cable. If the problem persists, see "Getting Help." 32 About Your System