Table 1-2. System Messages (continued) Message Causes Corrective Actions The following DIMMs should match in geometry: x,x,... The following DIMMs should match in rank count: x,x,... Invalid memory configuration. The specified memory modules do not match in size, number of ranks, or number of data lanes. Ensure that the memory modules are installed in a valid configuration. See "General Memory Module Installation Guidelines." The following DIMMs should match in size: x,x,... The following DIMMs should match in size and geometry: x,x,... The following DIMMs should match in size and rank count: x,x,... Thermal sensor A memory module without a Replace the memory not detected on x thermal sensor is installed in module. See "System the specified memory slot. Memory." Time-of-day clock stopped Faulty battery or faulty chip. See "Troubleshooting the System Battery." Time-of-day not Incorrect Time or Date set - please run settings; faulty system SETUP program battery. Check the Time and Date settings. See "Using the System Setup Program and UEFI Boot Manager." If the problem persists, replace the system battery. See "System Battery." About Your System 49