Table 1-2., System Messages, Message, Causes, Corrective Actions, ECC Memory Mode - memory configurations
View all Dell PowerEdge T610 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Table 1-2. System Messages Message Causes Corrective Actions 128-bit Advanced ECC mode disabled. For 128-bit Advanced ECC, DIMMs must be installed in pairs. Pairs must be matched in size and geometry. The Advanced ECC option Check other messages for a was enabled in BIOS, but is faulty memory module. no longer valid due to an Reconfigure the memory unsupported memory modules for Advanced ECC configuration, possibly a mode. See "System faulty or removed memory Memory." module. The Advanced ECC setting has been disabled. Alert! Advanced ECC Memory Mode disabled! Memory configuration does not support Advanced ECC Memory Mode. Advanced ECC Memory Mode was enabled in the system setup program, but the current configuration does not support Advanced ECC Memory Mode. A memory module may be faulty. Ensure that the memory modules are installed in a configuration that supports Advanced ECC Memory Mode. Check other system messages for additional information for possible causes. For memory configuration information, see "General Memory Module Installation Guidelines." If the problem persists, see "Troubleshooting System Memory." Alert! iDRAC6 not responding. Rebooting. The iDRAC6 is not Wait for the system to responding to BIOS reboot. communication either because it is not functioning properly or has not completed initialization. The system will reboot. 38 About Your System