System Messages - raid controller
View all Dell PowerEdge T610 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Table 1-1. LCD Status Messages (continued) Code Text Causes Corrective Actions W1228 RAID Controller battery capacity < 24hr. Warns predictively that the RAID battery has less than 24 hours of charge left. Allow RAID battery to charge to greater than 24 hours of sustained charge. If problem persists, replace RAID battery. See "Installing a RAID Battery." W1627 Power required The system configuration Turn off power to the > PSU wattage. requires more power than system, reduce the Check PSU and what the power supply can hardware configuration or config. provide. install higher-wattage power supplies, and then restart the system. W1628 Performance The system configuration Turn off power to the degraded. requires more power than system, reduce the Check PSU and what the power supply can hardware configuration or system provide, but it can boot if install higher-wattage configuration. throttled. power supplies, and then restart the system. NOTE: For the full name of an abbreviation or acronym used in this table, see the "Glossary." System Messages System messages appear on the screen to notify you of a possible problem with the system. NOTE: If you receive a system message not listed in the table, check the documentation for the application that is running when the message appears or the operating system's documentation for an explanation of the message and recommended action. About Your System 37