HP ML370 HP ProLiant ML370 Generation 3 Setup and Installation Guide - Page 111
Repeat steps 1 through 3 to replace additional fans as needed.
UPC - 613326765616
View all HP ML370 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 111 highlights
Installing Hardware Options To replace a hot-plug fan: 1. Squeeze the hot-plug fan handles together (1). 2. Lift the fan out of the fan cage (2). Figure 3-56: Removing a hot-plug fan 3. Slide the replacement hot-plug fan into the open fan cage slot and press down to seat the fan securely. 4. Repeat steps 1 through 3 to replace additional fans as needed. 5. Reinstall the access panel. 6. Power up the server and observe the internal system health LED on the front panel and the LEDs on all installed fans to be sure they are green. NOTE: If the front panel internal system health LED is not green after you install hot-plug fans, reseat the hot-plug fan or refer to Appendix D, "Troubleshooting," for diagnosis. 3-66 HP ProLiant ML370 Generation 3 Server Setup and Installation Guide