HP ML370 HP ProLiant ML370 Generation 3 Setup and Installation Guide - Page 238
Table E-7, System Board LEDs and Internal Health LED Status Combinations, System LED and Status
UPC - 613326765616
View all HP ML370 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 238 highlights
LED Indicators and Switches Table E-7: System Board LEDs and Internal Health LED Status Combinations System LED and Status Processor failure, socket X (amber) Internal Health LED Status Red Processor failure, both sockets (amber) PPM failure, slot X (amber) Amber Red Red DIMM failure, slot X (amber) Red Amber Means • Processor in socket X has failed. • Processor has failed over to offline spare, if the second processor is installed. • Processor is not installed in socket X. • ROM detects a failed processor during POST. Processor in socket X is in pre-failure condition. • Processor types do not match. • Processor is not installed, but the corresponding PPM is installed. • PPM in slot X has failed. • PPM X is not installed. • PPM is not installed, but the corresponding processor is installed. • DIMM in slot X has failed. • DIMM has experienced a multi-bit error. • DIMM has reached single-bit correctable error threshold. • DIMM in slot X is in pre-failure condition. continued HP ProLiant ML370 Generation 3 Server Setup and Installation Guide E-13