HP ML370 HP ProLiant ML370 Generation 3 Setup and Installation Guide - Page 239
System LED and Status, Internal Health, LED Status, Means
UPC - 613326765616
View all HP ML370 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 239 highlights
LED Indicators and Switches Table E-7: System Board LEDs and Internal Health LED Status Combinations continued System LED and Status Internal Health LED Status Means DIMM failure, all slots in Red one bank (amber) Interleaving error: The bank is not populated entirely or DIMMs do not all match within the bank. DIMM failure, all slots Red (amber) • No valid or usable memory is installed in the system. • The banks are not populated in the correct order. System overtemperature Red (amber) System has exceeded OS cautionary level or critical hardware level. Fan (amber) Power supply (off) Red Amber Red Amber A required fan has failed. A redundant fan has failed. Primary power supply or both power supplies have failed. Secondary power supply has failed. E-14 HP ProLiant ML370 Generation 3 Server Setup and Installation Guide