Page 213 highlights
Troubleshooting Diagnostic Steps If the server does not power up, or powers up but does not complete POST, answer the questions in Table D-1 to determine the appropriate actions. The flow of questions reflects the usual flow of events during a power-on sequence. Figure D-1 illustrates the recommended diagnostic steps and decision points. According to the answers you give, you are directed to the appropriate table in this section. That table outlines possible reasons for the problem, options available to assist in diagnosis, possible solutions, and references to other sources of information. Table D-1: Diagnostic Steps Question Question 1: Is the Power On/Standby LED amber? Question 2: Is the Power On/Standby LED green? Question 3: Is the external health LED green? Question 4: Is the internal health LED green? Question 5: Is the monitor displaying information? Action If yes, continue to question 2. If no, refer to Table D-2. If yes, continue to question 3. If no, refer to Table D-3. If yes, continue to question 4. If no, refer to Table D-4. If yes, continue to question 5. If no, refer to Table D-5. If yes, use the POST messages for further diagnosis. Refer to Table D-6 for details. If no, refer to Table D-6. HP ProLiant ML370 Generation 3 Server Setup and Installation Guide D-5