HP ML370 HP ProLiant ML370 Generation 3 Setup and Installation Guide - Page 207
Table C-1, POST Error Messages, Error Code, Audible, Beeps, Probable Source, of Problem, Action
UPC - 613326765616
View all HP ML370 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 207 highlights
Server Error Messages Table C-1: POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 207-Invalid Memory Configuration Unsupported DIMM In DIMM Socket X One long, Installed DIMMs do not and one short have ECC capability. Only ECC DIMMs Are Supported. 207-Invalid Memory Configuration Unsupported DIMM In DIMM Socket X One long, and one short Installed DIMMs in the same bank are of different sizes. DIMM Size Parameters Not Supported. 207-Invalid Memory Configuration - DIMMs must be installed sequentially. One long, Installed DIMMs are not and one short sequentially ordered. 207-Invalid Memory Configuration Incomplete bank detected in bank X One long, Bank is missing a and one short DIMM. 207-Invalid Memory Configuration - Mismatched DIMMs within DIMM Bank Memory in Bank X Not Utilized. 207-Memory Configuration Warning - DIMM in DIMM Socket X does not have Primary Width of 4 and only supports standard ECC. One long, and one short Installed DIMMs in the same bank are of different sizes. One long, Installed DIMMs have a and one short primary width of x8. Action Replace DIMMs in indicated slots. Refer to "Memory" in Chapter 3. Replace DIMMs in indicated slots. Refer to "Memory" in Chapter 3. Reinstall DIMMs in proper order. Refer to "Memory" in Chapter 3. Install a DIMM to fill the bank. Refer to "Memory" in Chapter 3. Replace DIMMs in indicated slots. Refer to "Memory" in Chapter 3. Install DIMMs that have a primary width of x4. Refer to "Memory" in Chapter 3. continued C-2 HP ProLiant ML370 Generation 3 Server Setup and Installation Guide