HP NetServer AA 4000 HP AA HP Netserver 4000 Reference Guide - Page 139
Reenabling faulted Components
View all HP NetServer AA 4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 139 highlights
Ch 7: Bsic Troubleshooting 4. When the NetRAID adapter boots a mismatch will occur between the disks and the NVRAM of the NetRAID adapter. When this occurs open the NetRAID Ctrl-M utility and save the disk configuration to NVRAM. Another solution here would be to copy the configuration from the NetRAID Adapter of the other IOP to floppy and restore on to the new NetRAID Adapter. 5. Save the configuration and boot the IOP into Online Mode. 6. Examine the Marathon Manager and enable any faulted devices. 7. Confirm the IOP joins the array and a re-mirroring begins. Reenabling faulted Components After completing a maintenance procedure, you may need to enable a component was previously disabled, faulted, or offline. If necessary, re-enable any faulted or disabled components using Marathon Manager commands, as follows: Troubleshooting Tips Never assume it is okay to reboot a system. In the past, troubleshooting Windows NT consisted of "reboot" and see if that fixes it. In an HA environment care must be take to ensure the entire system will not be taken down when a reboot is initiated. Avoid taking an IOP offline unless absolutely necessary. Removing an IOP and bringing it back online results in a disk re-mirror. When inserting a Marathon cable, carefully align the pins and press firmly. These cables take quite a bit of effort to seat them properly. Once they have been pressed seated firmly by hand, tighten the Network Server Division 7-23