Symantec 10521148 Implementation Guide - Page 65
Cabling a bypass unit for fail-open, using in-line mode, Network, segment 1
View all Symantec 10521148 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
Installing the 7100 Series 57 Cabling Figure 4-6 7160 using in-line mode Network segment 1 Network segment 2 Network segment 3 Network segment 4 7160 Network segment 1 Network segment 2 Network segment 3 Network segment 4 To cable the 7160 for in-line mode monitoring 1 Connect port 0 of the appliance to one side of network segment 1. 2 Connect port 1 of the appliance to the other side of network segment 1. 3 Connect port 2 of the appliance to one side of network segment 2. 4 Connect port 3 of the appliance to the other side of network segment 2. 5 Connect port 4 of the appliance to one side of network segment 3. 6 Connect port 5 of the appliance to the other side of network segment 3. 7 Connect port 6 of the appliance to one side of network segment 4. 8 Connect port 7 of the appliance to the other side of network segment 4. Cabling a bypass unit for fail-open This section describes how to install a Symantec Network Security In-line Bypass unit to provide fail-open capability. The 4 In-line Bypass unit is recommended for operation with the 7160.