Panasonic WJHD316A WJHD309A User Guide - Page 105

[System] Settings on System, Basic Setup] Basic system settings

Page 105 highlights

I [System] Settings on System Perform the following system settings required to operate this unit. G [Basic Setup] Basic system settings Perform the following settings for basic operation. SETUP MENU Advanced Basic Setup Time & Date User Regist. User Edit User Delete Host Regist. Host Edit Host Delete User Level Save/Load Quick Menu System Switcher Recording Display Event Comm I ADMIN Password ***** I PSD User ADMIN I Auto Login Auto Login User ADMIN I Auto Logout I Priority I "GO TO LAST" before I Language I Beep(Operation) I Buzzer(Error) I Shutdown Time I Auto Copy Schedule Maintenance LIVE ON OFF Follow the priority. 5s ENGLISH ON 2s 10s OFF 8 ADMIN Password Set the password for an administrator. Enter 4-8 alphanumeric characters. The same method is used to enter, insert and delete characters as for attaching text information to images. Refer to page 59 about the characters available. Important: To enhance the security, change the password for an administrator periodically. 8 PSD User When a user operates a controller compatible with PS·Data, operation will be restricted by the priority and operational level of the PSD user. A PSD user should be one of the users registered in this unit. 8 Auto Login Select ON and OFF whether or not to activate the auto login function. ON: Activates the auto login function. OFF: Does not activate the auto login function. It is neces- sary to perform the login operation every time this unit is started up. 8 Auto Login User When ON is selected for "Auto Login", the user registered as an auto login user in this setting can log into the unit automatically. An auto login user should be one of the users registered in this unit. 8 Auto Logout Select ON or OFF whether or not to activate the auto logout function. When ON is selected, auto logout will be carried out after a specified time has passed while displaying live images without operation. OFF: Does not activate the auto logout function. 1 min/2 min/3 min/4 min/5 min/30 min: Activates the auto logout function when the selected time has passed after login. Important: • The auto logout function will not be activated when ON is selected for "Auto Login". • Depending on the user level of the auto login user, operable functions may be different. 8 Priority Assign operating priorities when multiple users access this unit simultaneously from the following. Follow the priority: Operation by a user with a higher pri- ority will be performed. When the priorities of the first and the last accessed user are the same, post-priority will be applied. Pre-priority: Operation by the first accessed user will be performed regardless of priority. Post-priority: Operation by the last accessed user will be performed regardless of priority. 8 "GO TO LAST" before Select time to be skipped to when the "GO TO LAST" button is pressed during playback from the following. 5 s/10 s/30 s/1 min/5 min 8 Language Select a language for the SETUP MENU from the following. JAPANESE/ENGLISH/FRANÇAIS/ESPAÑOL/DEUTSCH/ ITALIANO/RUSSIAN/CHINESE Important: Displaying the language of the browser used to access the unit from a PC will not be changed even though this setting is changed. 8 Beep (Operation) Select ON or OFF whether or not to sound the buzzer when operating the buttons. ON: Sounds the buzzer when operating the buttons. OFF: Does not sound the buzzer when operating the but- tons. 8 Buzzer (Error) Select a buzzer operation when a problem has occurred from the following. OFF: Does not sound buzzer when a problem has occurred. 1 s - 30 s (in 1 second intervals)/40 s/50 s/1 min - 5 min (in 1 minute intervals): A buzzer will sound for the selected duration after a problem has occurred. EXT: The buzzer will sound continuously until the "ALARM RESET" button on the front panel of the unit is pressed. 105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182

105
Perform the following system settings required to operate
this unit.
[Basic Setup] Basic system settings
Perform the following settings for basic operation.
8
ADMIN Password
Set the password for an administrator.
Enter 4-8 alphanumeric characters.
The same method is used to enter, insert and delete char-
acters as for attaching text information to images. Refer to
page 59 about the characters available.
Important:
To enhance the security, change the password for an
administrator periodically.
8
PSD User
When a user operates a controller compatible with PS
·
Data,
operation will be restricted by the priority and operational
level of the PSD user.
A PSD user should be one of the users registered in this
unit.
8
Auto Login
Select ON and OFF whether or not to activate the auto login
function.
ON:
Activates the auto login function.
OFF:
Does not activate the auto login function. It is neces-
sary to perform the login operation every time this unit is
started up.
8
Auto Login User
When ON is selected for "Auto Login", the user registered
as an auto login user in this setting can log into the unit
automatically.
An auto login user should be one of the users registered in
this unit.
8
Auto Logout
Select ON or OFF whether or not to activate the auto logout
function.
When ON is selected, auto logout will be carried out after a
specified time has passed while displaying live images
without operation.
OFF:
Does not activate the auto logout function.
1 min/2 min/3 min/4 min/5 min/30 min:
Activates the auto
logout function when the selected time has passed after
login.
Important:
The auto logout function will not be activated when ON
is selected for "Auto Login".
Depending on the user level of the auto login user,
operable functions may be different.
8
Priority
Assign operating priorities when multiple users access this
unit simultaneously from the following.
Follow the priority:
Operation by a user with a higher pri-
ority will be performed. When the priorities of the first
and the last accessed user are the same, post-priority
will be applied.
Pre-priority:
Operation by the first accessed user will be
performed regardless of priority.
Post-priority:
Operation by the last accessed user will be
performed regardless of priority.
8
"GO TO LAST" before
Select time to be skipped to when the "GO TO LAST" button
is pressed during playback from the following.
5 s/10 s/30 s/1 min/5 min
8
Language
Select a language for the SETUP MENU from the following.
JAPANESE/ENGLISH/FRAN
Ç
AIS/ESPA
Ñ
OL/DEUTSCH/
ITALIANO/RUSSIAN/CHINESE
Important:
Displaying the language of the browser used to access
the unit from a PC will not be changed even though this
setting is changed.
8
Beep (Operation)
Select ON or OFF whether or not to sound the buzzer when
operating the buttons.
ON:
Sounds the buzzer when operating the buttons.
OFF:
Does not sound the buzzer when operating the but-
tons.
8
Buzzer (Error)
Select a buzzer operation when a problem has occurred
from the following.
OFF:
Does not sound buzzer when a problem has
occurred.
1 s - 30 s (in 1 second intervals)/40 s/50 s/1 min - 5 min
(in 1 minute intervals):
A buzzer will sound for the
selected duration after a problem has occurred.
EXT:
The buzzer will sound continuously until the "ALARM
RESET" button on the front panel of the unit is pressed.
[System] Settings on System
Schedule
Comm
Switcher
SETUP MENU
LIVE
Recording
Event
Display
System
Maintenance
ADMIN Password
PSD User
Auto Login
Auto Login User
Auto Logout
Priority
"GO TO LAST" before
Language
Beep(Operation)
Buzzer(Error)
Shutdown Time
Auto Copy
*****
OFF
ON
ADMIN
ADMIN
Follow the priority.
5s
ENGLISH
ON
2s
10s
OFF
Advanced
Basic Setup
Time & Date
User Regist.
User Edit
User Delete
Host Regist.
Host Edit
Host Delete
User Level
Save/Load
Quick Menu