Panasonic WJHD316A WJHD309A User Guide - Page 167

Event, Schedule, Setup Menu, Setup Item, Parameter, Default Setting

Page 167 highlights

Setup Menu Setup Item Parameter Default Setting *1 Emergency REC Resolution Recording Time Recording Rate and Quality Auto Copy FRAME 3D ON/FRAME 3D OFF/FIELD/SIF FIELD 1 s/2 s/..../10 s/20 s/30 s/1 min/2 min/..../10 min/ 20 min/30 min40 min/50 min/60 min/MANUAL/ CONTINUE 10 s Recording rate: 1 ips/2 ips/3 ips/5 ips/6 ips/ 7.5 ips/10 ips/15 ips/30 ips/60 ips 3 ips Quality: SFA/SFB/FQA/FQB/NQA/NQB/ EXA/EXB SFB OFF/ON OFF Event Event Setup Alarm Output Output Terminal Buzzer Monitor1 Action Monitor2 Action VMD Setup Alarm Setup Terminal Setup (SETUP AREA) (SETUP ALL AREA) (DELETE AREA) (DELETE ALL AREA) (SENSITIVITY) (VMD MODE) (EXIT) Alarm Auto Reset Alarm Disarm Time Terminal Setup OFF/1 s/2 s/...../30 s/40 s/50 s/1 min/ 2 min/...../5 min/EXT VMD: OFF Video Loss: -Terminal/Command Alarm: 2 s HD316A: TRM1/TRM2/...../TRM16 HD309A: TRM1/TRM2/...../TRM9 HD316A: CAM1: TRM1, CAM2: TRM2, .....CAM16: TRM16 HD309A: CAM1: TRM1, CAM2: TRM2, N .....CAM9: TRM9 (This setting is available only for "VMD" and "Terminal Alarm".) OFF/1 s/2 s/...../30 s/40 s/50 s/1 min/ 2 min/...../5 min/EXT VMD: OFF Video Loss: 2 s Terminal/Command Alarm: 2 s HD316A: OFF/CAM1/CAM2/...../CAM16 HD309A: OFF/CAM1/CAM2/...../CAM9 VMD: OFF Video Loss: Camera channel with a video loss occurrence N Terminal/Command Alarm: Same number for camera channel number and alarm number HD316A: OFF/CAM1/CAM2/...../CAM16 HD309A: OFF/CAM1/CAM2/...../CAM9 VMD: OFF Video Loss: Camera channel with a video loss occurrence N Terminal/Command Alarm: Same number for camera channel number and alarm number - - - - - - - - LOW/MID/HIGH/OFF OFF ANY AREA/VECTOR/DURATION ANY AREA - - OFF/1 s/2 s/...../30 s/40 s/50 s/1 min/2 min/3 min/ OFF 4 min/5 min 2 s/3 s/...../10 s 2 s N.O./N.C. N.O. Schedule Time Table Period 12:00AM to 12:00AM REC PROGRAM EVENT PROGRAM FTP SEND BY PERIODIC TIMER ERROR REPORT MAIL WARNING REPORT MAIL NW BANDWIDTH CONTROL PROG1/PROG2/PROG3/PROG4 PROG1/PROG2/PROG3/PROG4 ON/OFF ON/OFF ON/OFF OFF/32kbps/64kbps/128kbps/256kbps/ 512kbps/1024kbps/2Mbps/5Mbps/10Mbps 12:00AM to 12:00AM (Everyday/Time zone1) --:-- to --:-- (Except above) PROG1 PROG1 OFF OFF OFF OFF 167

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182

167
Emergency REC
Resolution
FRAME 3D ON/FRAME 3D OFF/FIELD/SIF
FIELD
Recording Time
1 s/2 s/
....
/10 s/20 s/30 s/1 min/2 min/
....
/10 min/
20 min/30 min40 min/50 min/60 min/MANUAL/
CONTINUE
10 s
Recording Rate and Quality
Recording rate: 1 ips/2 ips/3 ips/5 ips/6 ips/
7.5 ips/10 ips/15 ips/30 ips/60 ips
3 ips
Quality: SFA/SFB/FQA/FQB/NQA/NQB/
EXA/EXB
SFB
Auto Copy
OFF/ON
OFF
Event
Event Setup
Alarm Output
OFF/1 s/2 s/
.....
/30 s/40 s/50 s/1 min/
VMD: OFF
2 min/
.....
/5 min/EXT
Video Loss: --
Terminal/Command Alarm: 2 s
Output Terminal
HD316A: TRM1/TRM2/
.....
/TRM16
HD316A: CAM1: TRM1, CAM2: TRM2,
.....
CAM16: TRM16
HD309A: TRM1/TRM2/
.....
/TRM9
HD309A: CAM1: TRM1, CAM2: TRM2,
N
.....
CAM9: TRM9
(This setting is available only for
"VMD" and "Terminal Alarm".)
Buzzer
OFF/1 s/2 s/
.....
/30 s/40 s/50 s/1 min/
VMD: OFF
2 min/
.....
/5 min/EXT
Video Loss: 2 s
Terminal/Command Alarm: 2 s
Monitor1 Action
HD316A: OFF/CAM1/CAM2/
.....
/CAM16
VMD: OFF
HD309A: OFF/CAM1/CAM2/
.....
/CAM9
Video Loss: Camera channel with
a video loss occurrence
N
Terminal/Command Alarm: Same
number for camera channel number
and alarm number
Monitor2 Action
HD316A: OFF/CAM1/CAM2/
.....
/CAM16
VMD: OFF
HD309A: OFF/CAM1/CAM2/
.....
/CAM9
Video Loss: Camera channel with
a video loss occurrence
N
Terminal/Command Alarm: Same
number for camera channel number
and alarm number
VMD Setup
(SETUP AREA)
-
-
(SETUP ALL AREA)
-
-
(DELETE AREA)
-
-
(DELETE ALL AREA)
-
-
(SENSITIVITY)
LOW/MID/HIGH/OFF
OFF
(VMD MODE)
ANY AREA/VECTOR/DURATION
ANY AREA
(EXIT)
-
-
Alarm Setup
Alarm Auto Reset
OFF/1 s/2 s/
.....
/30 s/40 s/50 s/1 min/2 min/3 min/
OFF
4 min/5 min
Alarm Disarm Time
2 s/3 s/
.....
/10 s
2 s
Terminal Setup
Terminal Setup
N.O./N.C.
N.O.
Schedule
Time Table
Period
12:00AM to 12:00AM
12:00AM to 12:00AM (Everyday/Time
zone1)
--:-- to --:-- (Except above)
REC PROGRAM
PROG1/PROG2/PROG3/PROG4
PROG1
EVENT PROGRAM
PROG1/PROG2/PROG3/PROG4
PROG1
FTP SEND BY PERIODIC
ON/OFF
OFF
TIMER
ERROR REPORT MAIL
ON/OFF
OFF
WARNING REPORT MAIL
ON/OFF
OFF
NW BANDWIDTH CONTROL
OFF/32kbps/64kbps/128kbps/256kbps/
OFF
512kbps/1024kbps/2Mbps/5Mbps/10Mbps
Setup Menu
Setup Item
Parameter
Default Setting
*1