Panasonic WJHD316A WJHD309A User Guide - Page 88

Connection for the Auto Adjust Time function

Page 88 highlights

Earth Sensor input Alarm input Alarm reset input Series recording input Time adjust input Earth Alarm output Alarm reset output Alarm recording During recording Disk Buzzer output System error output Temperature error output Time adjust output Series recording output G Connection for the Auto Adjust Time function • When "Auto Adjust Time" of "System" on the SETUP MENU is set to "MASTER" "Time Adjust Output" becomes available and the clock of this unit can be applied to other units. (Earth) (Time adjust output) !3 @0 Terminal block of other units Front LED monitor output ALARM/CONTROL • When "Auto Adjust Time" of "System" on the SETUP MENU is set to "SLAVE" "Time Adjust Input" becomes available. When a signal output from other equipment is supplied to the time adjust I/O terminals between 00 minutes 00 seconds and 14 minutes 59 seconds every hour or between 45 minutes 00 seconds and 59 minutes 59 seconds every hour, the clock will be set to "00 minutes 00 seconds" of the closest hour. Example: Signal is supplied at 2:50:00 (hour:minute:second)pm → Set at 3:00:00 pm Signal input supplied at 3:14:45 pm → Set at 3:00:00 pm Signal is supplied at 3:20:00 pm → Time will not be adjusted. (Earth) (Time adjust input) !3 @0 Terminal block of other units Front LED monitor output Earth Sensor input Alarm input Alarm reset input Series recording input Time adjust input Earth Alarm output Alarm reset output Alarm recording During recording Disk Buzzer output System error output Temperature error output Time adjust output Series recording output ALARM/CONTROL Important: • When "SLAVE" is selected, the auto time adjustment function works differently depending on the recording status as follows: When no recording is being performed When manual recording is being performed When schedule recording is being performed When event recording is being performed *1 When emergency recording is being performed The clock will be adjusted when the clock becomes inaccurate beyond ±5 seconds. The clock will not be adjusted. *1: When event recording is performed on any camera channel • Recording will not be performed for around 4 seconds when the clock is adjusted during recording. 88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182

88
Connection for the Auto Adjust Time function
When "Auto Adjust Time" of "System" on the SETUP MENU is set to "MASTER"
"Time Adjust Output" becomes available and the clock of this unit can be applied to other units.
When "Auto Adjust Time" of "System" on the SETUP MENU is set to "SLAVE"
"Time Adjust Input" becomes available. When a signal output from other equipment is supplied to the time adjust I/O terminals
between 00 minutes 00 seconds and 14 minutes 59 seconds every hour or between 45 minutes 00 seconds and 59 minutes
59 seconds every hour, the clock will be set to "00 minutes 00 seconds" of the closest hour.
Example:
Signal is supplied at 2:50:00 (hour:minute:second)pm
Set at 3:00:00 pm
Signal input supplied at 3:14:45 pm
Set at 3:00:00 pm
Signal is supplied at 3:20:00 pm
Time will not be adjusted.
Important:
When
SLAVE" is selected, the auto time adjustment function works differently depending on the recording status as fol-
lows:
*1
:
When event recording is performed on any camera channel
Recording will not be performed for around 4 seconds when the clock is adjusted during recording.
Terminal block of other units
(Time adjust output)
(Earth)
ALARM/CONTROL
Earth
Sensor input
Alarm input
Alarm reset input
Series recording input
Time adjust input
Earth
Alarm output
Alarm reset output
Alarm recording
During recording
Disk
Buzzer output
System error output
Temperature error output
Time adjust output
Series recording output
!
3
@
0
Front LED
monitor
output
ALARM/CONTROL
Terminal block of other units
Earth
Sensor input
Alarm input
Alarm reset input
Series recording input
Time adjust input
Earth
Alarm output
Alarm reset output
Alarm recording
During recording
Disk
Buzzer output
System error output
Temperature error output
Time adjust output
Series recording output
Front LED
monitor
output
(Time adjust input)
(Earth)
!
3
@
0
When no recording is being performed
When manual recording is being performed
When schedule recording is being performed
The clock will be adjusted when the clock becomes inaccu-
rate beyond ±5 seconds.
When event recording is being performed
*1
When emergency recording is being performed
The clock will not be adjusted.