Dell PowerConnect B-RX16 Installation Guide - Page 198

Considerations when using the feature

Page 198 highlights

7 Upgrading the BigIron RX Series software Using this feature, you can upgrade the Multi-Service IronWare software without a loss of service or disruption in the following supported functions and protocols: • All ports and links remain operational • TOS-based QoS • Layer-2 Switching • Layer-2 Protocols: • MRP • STP • VSRP • RSTP • MSTP Considerations when using the feature Consider the following when using this feature: • You must have both active and standby management modules installed to use this feature. • To avoid any disruptions of Layer-3 traffic to OSPF or BGP routes, the router must be configured with OSPF Graceful Restart and BGP Graceful Restart features. In addition, the device's OSFP neighbors must have OSPF Graceful Restart Helper enabled. • The total time it takes for the hitless upgrade process to finish varies between approximately 1 and 10 minutes. This depends on the size of the MAC table, the number of OSPF and BGP neighbors and the size of the routing table. Router configuration is unavailable during the entire hitless upgrade process. The message "---SW Upgrade In Progress - Please Wait---" is printed at the console when configuration is attempted. Operational command of the router is allowed during the upgrade process. • The active management module changes from the initial active management module to the standby management module during the hitless upgrade process. This makes it necessary to have a connection to the console interface on both management modules. • Upon being reset, the management and interface module CPUs are unable to send and receive any packets. Once the management and interface modules are up and running, their CPUs are able to send and receive packets, even before the hitless upgrade process is complete. • Router configuration is not allowed to be changed during the entire hitless upgrade process. • System-max parameter changes or other configuration changes that require a system reload such as "cam-mode" and cam-profile" changes do not take effect upon hitless upgrade. • FPGA images cannot be upgraded using the hitless upgrade process. • This feature cannot be used to downgrade an image to an older major version than the version that the device is currently running. • If there are protocol dependencies between neighboring nodes, it is recommended that only each node is upgraded: one node at a time. • After hitless upgrade, the BigIron RX router will still have the same running configuration as it does before the upgrade. A configuration that is not saved before hitless reload is not removed and the existing startup configuration does not take effect. This behavior is the same as displayed by the management module switchover feature. 186 BigIron RX Installation Guide 53-1001811-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240

186
BigIron RX Installation Guide
53-1001811-01
Upgrading the BigIron RX Series software
7
Using this feature, you can upgrade the Multi-Service IronWare software without a loss of service or
disruption in the following supported functions and protocols:
All ports and links remain operational
TOS-based QoS
Layer-2 Switching
Layer-2 Protocols:
MRP
STP
VSRP
RSTP
MSTP
Considerations when using the feature
Consider the following when using this feature:
You must have both active and standby management modules installed to use this feature.
To avoid any disruptions of Layer-3 traffic to OSPF or BGP routes, the router must be configured
with OSPF Graceful Restart and BGP Graceful Restart features. In addition, the device’s OSFP
neighbors must have OSPF Graceful Restart Helper enabled.
The total time it takes for the hitless upgrade process to finish varies between approximately 1
and 10 minutes. This depends on the size of the MAC table, the number of OSPF and BGP
neighbors and the size of the routing table. Router configuration is unavailable during the
entire hitless upgrade process. The message "
---SW Upgrade In Progress - Please Wait---
" is
printed at the console when configuration is attempted. Operational command of the router is
allowed during the upgrade process.
The active management module changes from the initial active management module to the
standby management module during the hitless upgrade process. This makes it necessary to
have a connection to the console interface on both management modules.
Upon being reset, the management and interface module CPUs are unable to send and receive
any packets. Once the management and interface modules are up and running, their CPUs are
able to send and receive packets, even before the hitless upgrade process is complete.
Router configuration is not allowed to be changed during the entire hitless upgrade process.
System-max parameter changes or other configuration changes that require a system reload
such as "cam-mode" and cam-profile" changes do not take effect upon hitless upgrade.
FPGA images cannot be upgraded using the hitless upgrade process.
This feature cannot be used to downgrade an image to an older major version than the version
that the device is currently running.
If there are protocol dependencies between neighboring nodes, it is recommended that only
each node is upgraded: one node at a time.
After hitless upgrade, the BigIron RX router will still have the same running configuration as it
does before the upgrade. A configuration that is not saved before hitless reload is not removed
and the existing startup configuration does not take effect. This behavior is the same as
displayed by the management module switchover feature.