Dell PowerConnect B-RX16 Installation Guide - Page 94

Desired and abnormal LED states after system power on, Continued, Interface module, Desired state

Page 94 highlights

2 Verifying proper operation TABLE 13 LED Desired and abnormal LED states after system power on (Continued) Desired state Meaning Abnormal state Meaning or action Interface module Pwr Mgmt Act On The module is Off receiving power. During initialization: steady blinking. After initialization: occasional blinking. The active management module's processor and the interface module's processor are communicating. Off for an extended period. The module is not receiving power. You can do the following: • Make certain that the module is installed properly. For more information, refer to "Installing BigIron RX-4 modules" on page 33, "Installing BigIron RX-8 modules" on page 42, "Installing BigIron RX-16 modules" on page 52, or "Installing BigIron RX-32 modules" on page 62. • The module may not be receiving enough power. Brocade recommends installing power supplies in a fully redundant configuration as described in "Installing power supplies in a BigIron RX-4 chassis" on page 35, "Installing power supplies in the BigIron RX-8 chassis" on page 44, "Installing power supplies in a BigIron RX-16 chassis" on page 54, or "Installing power supplies in a BigIron RX-32 chassis" on page 75. • Check the Pwr LED on the management module. If it is on, this module may be holding the power from the interface module. • Enter the show chassis command at any level of the CLI to determine if the management module recognizes the presence of all power sources. • If using AC power supplies, see the entry for the AC power supply LED in this table for more information. The interface module may be in interactive mode. Check the status of the module by entering the show module command at any CLI prompt. 82 BigIron RX Installation Guide 53-1001811-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240

82
BigIron RX Installation Guide
53-1001811-01
Verifying proper operation
2
Interface module
Pwr
On
The module is
receiving power.
Off
The module is not receiving power.
You can do the following:
Make certain that the
module is installed properly.
For more information, refer to
“Installing BigIron RX-4
modules”
on page 33,
“Installing BigIron RX-8
modules”
on page 42,
“Installing BigIron RX-16
modules”
on page 52, or
“Installing BigIron RX-32
modules”
on page 62.
The module may not be
receiving enough power.
Brocade recommends
installing power supplies in a
fully redundant configuration
as described in
“Installing
power supplies in a BigIron
RX-4 chassis”
on page 35,
“Installing power supplies in
the BigIron RX-8 chassis”
on
page 44,
“Installing power
supplies in a BigIron RX-16
chassis”
on page 54, or
“Installing power supplies in
a BigIron RX-32 chassis”
on
page 75.
Check the Pwr LED on the
management module. If it is
on, this module may be
holding the power from the
interface module.
Enter the
show chassis
command at any level of the
CLI to determine if the
management module
recognizes the presence of
all power sources.
If using AC power supplies,
see the entry for the AC
power supply LED in this
table for more information.
Mgmt Act
During
initialization:
steady blinking.
After initialization:
occasional
blinking.
The active
management
module’s processor
and the interface
module’s processor
are communicating.
Off for an
extended
period.
The interface module may be in
interactive mode. Check the
status of the module by entering
the
show module
command at any
CLI prompt.
TABLE 13
Desired and abnormal LED states after system power on
(Continued)
LED
Desired state
Meaning
Abnormal
state
Meaning or action