Yamaha M7CL M7cl V3 Owner's Manual - Page 176

GEQ ON/OFF button, GEQ LINK button

Page 176 highlights

Graphic EQ operations 1 Rack select tabs These tabs switch between racks 1-8. For a rack in which a Flex15GEQ is mounted, the tabs will be split as xA and xB (x is the rack number). B INPUT button This button displays the OUTPUT CH SELECT popup window, where you can select the input source of the rack. The operating procedure is the same as for the INPUT button in the GEQ/EFFECT field. C OUTPUT button This button displays the INPUT CH SELECT popup window, where you can select the output destination of the rack. The operating procedure is the same as for the OUTPUT button in the GEQ/EFFECT field. D GEQ LINK button This button links adjacent GEQ units. In the case of a 31BandGEQ, the GEQ units in adjacent odd-numbered/even-numbered racks will be linked. In the case of a Flex15GEQ, the GEQ (A) and GEQ (B) within the same rack will be linked. NOTE • The GEQ LINK button is shown only if linking is possible. E FLAT button This returns all bands of the currently selected GEQ to 0 dB. F GEQ ON/OFF button Switches the currently selected GEQ on/off. 3 If you're using a stereo source, link the two GEQ units. You will be able to use the GEQ LINK button if you have selected a 31BandGEQ or Flex15GEQ for adjacent odd-numbered/even-numbered racks. When you turn this button on, the following popup window will appear. To enable linking, press any button other than CANCEL. The popup window contains the following items. C RESET BOTH button The parameters of both will be initialized, and then linked. D CANCEL button Cancels the link and closes the popup window. When you link GEQ units, a symbol will appear in the GEQ/EFFECT field to indicate the linked status. Indicate the linked status 4 Press the GEQ ON/OFF button to turn the GEQ on. After you've turned the GEQ on, adjust the bands of the GEQ. For details on operating the GEQ, refer to "Using the 31BandGEQ" that follows or "Using the Flex15GEQ" (→ p. 178). HINT • The rack in the GEQ/EFFECT field shows the input/output levels of the GEQ. 1 2 3 4 1 GEQ x→y button ("x" and "y" are the rack number, or the rack number and the alphabetical characters A or B) The parameters of "x" will be copied to "y," and then linked. B GEQ y→x button The parameters of "y" will be copied to "x," and then linked. 176 M7CL Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312

M7CL
Owner’s Manual
Graphic EQ operations
176
1
Rack select tabs
These tabs switch between racks 1–8. For a rack in
which a Flex15GEQ is mounted, the tabs will be split
as xA and xB (x is the rack number).
B
INPUT button
This button displays the OUTPUT CH SELECT
popup window, where you can select the input source
of the rack. The operating procedure is the same as for
the INPUT button in the GEQ/EFFECT field.
C
OUTPUT button
This button displays the INPUT CH SELECT popup
window, where you can select the output destination of
the rack. The operating procedure is the same as for
the OUTPUT button in the GEQ/EFFECT field.
D
GEQ LINK button
This button links adjacent GEQ units. In the case of a
31BandGEQ, the GEQ units in adjacent odd-num-
bered/even-numbered racks will be linked. In the case
of a Flex15GEQ, the GEQ (A) and GEQ (B) within
the same rack will be linked.
E
FLAT button
This returns all bands of the currently selected GEQ to
0 dB.
F
GEQ ON/OFF button
Switches the currently selected GEQ on/off.
3
If you’re using a stereo source, link the two
GEQ units.
You will be able to use the GEQ LINK button if you
have selected a 31BandGEQ or Flex15GEQ for adja-
cent odd-numbered/even-numbered racks. When you
turn this button on, the following popup window will
appear. To enable linking, press any button other than
CANCEL. The popup window contains the following
items.
1
GEQ x
y button (“x” and “y” are the
rack number, or the rack number and the
alphabetical characters A or B)
The parameters of “x” will be copied to “y,” and then
linked.
B
GEQ y
x button
The parameters of “y” will be copied to “x,” and then
linked.
C
RESET BOTH button
The parameters of both will be initialized, and then
linked.
D
CANCEL button
Cancels the link and closes the popup window.
When you link GEQ units, a symbol will appear in the
GEQ/EFFECT field to indicate the linked status.
4
Press the GEQ ON/OFF button to turn the
GEQ on.
After you’ve turned the GEQ on, adjust the bands of
the GEQ. For details on operating the GEQ, refer to
“Using the 31BandGEQ” that follows or “Using the
Flex15GEQ” (
p. 178).
The GEQ LINK button is shown only if linking is possible.
NOTE
1
2
3
4
Indicate the linked status
The rack in the GEQ/EFFECT field shows the input/output
levels of the GEQ.
HINT