Yamaha M7CL M7cl V3 Owner's Manual - Page 243

Changing the EtherSound settings from AVS-ESMonitor (M7CL-48ES

Page 243 highlights

Changing the EtherSound settings from AVS-ESMonitor (M7CL-48ES) Changing the EtherSound settings from AVS-ESMonitor (M7CL-48ES) Follow the steps below to change the EtherSound settings from AVS-ES Monitor. (For example, when you want to connect an EtherSound device other than the SB168-ES units.) 1 Set SB168-ES dip switches 5-8 to OFF (up). 2 Press the AUTO CONFIGURE button to turn it off (the button indicator will turn off). 3 Connect a computer (with AVS-ESMonitor installed) to the [3rd] connector on the M7CL-48ES. 4 Start AVS-ESMonitor. 5 Select the desired EtherSound device (such as an M7CL-48ES, SB168-ES, etc.) for which you want to modify the settings from AVS-ESMonitor, then open the Control page. 6 Remove the check from Lock Inputs and Lock Outputs in the Lock Routing section on the Control page. 7 Modify the settings from AVS-ESMonitor as necessary. 8 If necessary, execute "Write to Non Volatile Memory" to write the modified data to Non Volatile Memory (non-volatile memory of the EtherSound module). NOTE • If the AUTO CONFIGURE button has been turned on, the Stage Box Setup function of the M7CL-48ES will take priority. Thus the setting data written to non-volatile memory will not affect either the M7CL-48ES or SB168-ES. If you want to use the setting data that was written to non-volatile memory, leave the AUTO CONFIGURE button off (the button indicator is turned off). • If you turn on the power to the SB168-ES while dip switches 5-8 are set to OFF (up), settings written to non-volatile memory will be used at the time of startup. • By viewing the "Setting from DIP Switch 5-8" section of the SB168-ES Control page in AVS-ESMonitor, you can check the M7CL-48ES's connection type as specified via SB168-ES dip switches 5-8. In the same way, you can check the Stage Box Setup function settings of the M7CL48ES by viewing the AUTO CONFIGURE section of the M7CL-48ES Control page. You can modify these settings temporarily from AVS-ESMonitor. 20 Other functions M7CL Owner's Manual 243

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312

Changing the EtherSound settings from AVS-ESMonitor (M7CL-48ES)
M7CL
Owner’s Manual
243
Other functions
20
Follow the steps below to change the EtherSound settings from AVS-ES Monitor. (For example,
when you want to connect an EtherSound device other than the SB168-ES units.)
1
Set SB168-ES dip switches 5–8 to OFF (up).
2
Press the AUTO CONFIGURE button to turn
it off (the button indicator will turn off).
3
Connect a computer (with AVS-ESMonitor
installed) to the [3rd] connector on the
M7CL-48ES.
4
Start AVS-ESMonitor.
5
Select the desired EtherSound device (such
as an M7CL-48ES, SB168-ES, etc.) for
which you want to modify the settings from
AVS-ESMonitor, then open the Control
page.
6
Remove the check from Lock Inputs and
Lock Outputs in the Lock Routing section
on the Control page.
7
Modify the settings from AVS-ESMonitor as
necessary.
8
If necessary, execute “Write to Non Volatile
Memory” to write the modified data to Non
Volatile Memory (non-volatile memory of
the EtherSound module).
Changing the EtherSound settings from AVS-ESMonitor (M7CL-48ES)
If the AUTO CONFIGURE button has been turned on, the
Stage Box Setup function of the M7CL-48ES will take priority.
Thus the setting data written to non-volatile memory will not
affect either the M7CL-48ES or SB168-ES. If you want to use
the setting data that was written to non-volatile memory, leave
the AUTO CONFIGURE button off (the button indicator is
turned off).
If you turn on the power to the SB168-ES while dip switches
5–8 are set to OFF (up), settings written to non-volatile mem-
ory will be used at the time of startup.
By viewing the “Setting from DIP Switch 5–8” section of the
SB168-ES Control page in AVS-ESMonitor, you can check
the M7CL-48ES’s connection type as specified via SB168-ES
dip switches 5–8. In the same way, you can check the Stage
Box Setup function settings of the M7CL48ES by viewing the
AUTO CONFIGURE section of the M7CL-48ES Control page.
You can modify these settings temporarily from AVS-ESMoni-
tor.
NOTE