Yamaha M7CL M7cl V3 Owner's Manual - Page 178

Using the Flex15GEQ

Page 178 highlights

Graphic EQ operations 6 Repeat steps 4 and 5 to adjust each band. HINT • If you switch the display to a different screen or rack, the fader assignments of the Centralogic section will forcibly be defeated. However if you once again display the same rack, the group of bands you had previously been controlling will automatically be assigned to the faders. 7 When you've finished making settings, turn off the buttons of the FADER ASSIGN field. The faders and [ON] keys of the Centralogic section will return to their previous function. HINT • When you close the GEQ popup window, the buttons in the FADER ASSIGN field automatically turn off. 8 If you want to copy the currently-displayed 31BandGEQ settings to the 31BandGEQ of another rack, or to initialize the settings, you can do so using the tool buttons at the top of the popup window. For details on how to use these buttons, refer to "Using the tool buttons" (→ p. 35). NOTE • Only 31BandGEQ settings that use less than fifteen bands can be copied to a Flex15GEQ. HINT • GEQ settings can be saved/loaded at any time using the dedicated library (→ p. 35). Using the Flex15GEQ You will use the Centralogic section's faders 1-8 and [ON] keys to control the Flex15GEQ. 1 Refer to steps 1-6 in the "Virtual rack operations" (→ p. 172) to mount a Flex15GEQ in a rack and set its input source and output destination. A rack in which a Flex15GEQ is mounted will show information for two GEQ units (A and B). 3 4 1 2 1 GEQ (A) B GEQ (B) C Rack graphic display area D Input/output meters This indicates the level of the signals before and after the Flex15GEQ. The levels for two GEQ units (A and B) are shown. HINT • When you mount a Flex15GEQ, two monaural 31BandGEQ units are placed in a single rack. However, only up to fifteen bands can be adjusted for each unit. 2 Press the rack in which you mounted the Flex15GEQ. The GEQ popup window for GEQ (A) or GEQ (B) will appear. 56 178 M7CL Owner's Manual 1 2 3 4 1 EQ graph This indicates the approximate response of the current Flex15GEQ settings. B Faders These faders indicate the amount of boost/cut for each band of the Flex15GEQ. The actual values are shown in the numerical boxes below. C FADER ASSIGN field In this field you can select the group of bands that will be controlled by the faders. "AVAILABLE BANDS" is a realtime indication of the remaining number of bands (maximum 15) that can be controlled for the current GEQ.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312

M7CL
Owner’s Manual
Graphic EQ operations
178
6
Repeat steps 4 and 5 to adjust each band.
7
When you’ve finished making settings, turn
off the buttons of the FADER ASSIGN field.
The faders and [ON] keys of the Centralogic section
will return to their previous function.
8
If you want to copy the currently-displayed
31BandGEQ settings to the 31BandGEQ of
another rack, or to initialize the settings,
you can do so using the tool buttons at the
top of the popup window.
For details on how to use these buttons, refer to “Using
the tool buttons” (
p. 35).
You will use the Centralogic section’s faders 1–8 and
[ON] keys to control the Flex15GEQ.
1
Refer to steps 1–6 in the “Virtual rack oper-
ations” (
p. 172) to mount a Flex15GEQ in
a rack and set its input source and output
destination.
A rack in which a Flex15GEQ is mounted will show
information for two GEQ units (A and B).
1
GEQ (A)
B
GEQ (B)
C
Rack graphic display area
D
Input/output meters
This indicates the level of the signals before and after
the Flex15GEQ. The levels for two GEQ units (A and
B) are shown.
2
Press the rack in which you mounted the
Flex15GEQ.
The GEQ popup window for GEQ (A) or GEQ (B)
will appear.
1
EQ graph
This indicates the approximate response of the current
Flex15GEQ settings.
B
Faders
These faders indicate the amount of boost/cut for each
band of the Flex15GEQ. The actual values are shown
in the numerical boxes below.
C
FADER ASSIGN field
In this field you can select the group of bands that will
be controlled by the faders. “AVAILABLE BANDS” is
a realtime indication of the remaining number of
bands (maximum 15) that can be controlled for the
current GEQ.
If you switch the display to a different screen or rack, the fader
assignments of the Centralogic section will forcibly be
defeated. However if you once again display the same rack,
the group of bands you had previously been controlling will
automatically be assigned to the faders.
HINT
When you close the GEQ popup window, the buttons in the
FADER ASSIGN field automatically turn off.
HINT
Only 31BandGEQ settings that use less than fifteen bands
can be copied to a Flex15GEQ.
NOTE
GEQ settings can be saved/loaded at any time using the ded-
icated library (
p. 35).
HINT
Using the Flex15GEQ
4
3
1
2
When you mount a Flex15GEQ, two monaural 31BandGEQ
units are placed in a single rack. However, only up to fifteen
bands can be adjusted for each unit.
HINT
4
3
2
1
5
6