D-Link DWS-3160-24TC DWS-3160 Series Web UI Reference Guide - Page 31
IP Interface, System IP Address Settings
View all D-Link DWS-3160-24TC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
DWS-3160 Series Gigabit Ethernet Unified Switch Web UI Reference Guide Figure 6-6 IPv6 Neighbor Settings window The fields that can be configured are described below: Parameter Description Interface Name Enter the interface name of the IPv6 neighbor. Neighbor IPv6 Address Enter the neighbor IPv6 address. Link Layer MAC Address Enter the link layer MAC address. Interface Name Enter the name of the IPv6 neighbor. Tick the All check box to search for all current interfaces on the Switch. State Use the drop-down menu to select All, Address, Static, or Dynamic. When the user selects address from the drop-down menu, the user will be able to enter an IP address in the space provided next to the state option. Click the Add button to add a new entry based on the information entered. Click the Find button to locate a specific entry based on the information entered. Click the Clear button to clear all the information entered in the fields. IP Interface System IP Address Settings The IP address may initially be set using the console interface prior to connecting to it through the Ethernet. The Web manager will display the Switch's current IP settings. NOTE: The Switch's factory default IP address is 10.90.90.90 with a subnet mask of 255.0.0.0 and a default gateway of 0.0.0.0. 26