HP Designjet 5000 Service Manual - Page 141
Service Station Calibration, Station in relation to the Carriage Assembly. The Service Station
View all HP Designjet 5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 141 highlights
Service Calibrations 2. Service Station Calibration PHONE SUPPORT The purpose of this Service Calibration is to calibrate the Service Station in relation to the Carriage Assembly. The Service Station Calibration performs the following calibrations: n Line Sensor to Black Pen. n Drop Detector. n Primer. NOTE Perform the Service Station Calibration whenever: n Carriage Assembly is disassembled or replaced. n Service Station is disassembled or replaced. If you get an error code, refer to Page 5-26, Calibration Error Codes for its description and resolution. NOTE Perform the Service Station Calibration as follows: To perform this Calibration, make sure you load white medium that is the full width of the Printer. 1. In the Service Calibrations submenu, scroll to "2.2 Service Station" and press Enter. Top 2 Service Calibrations... Back 2.1 Scan axis 2.2 Service Station 2.3 ACCURACY ↑ Make Selection ↓ Enter Press Enter If the Media loaded is not the right size, the following message is displayed. Press Enter to exit. Load the correct media and repeat the procedure. 2.2 Service Station Media too small. Remove Media. Press ENTER to continue Top Back ↑ ↓ Enter Press Enter HP DesignJet 5000 Series Printers Service Manual 5-11