Dell PowerEdge R905 Hardware Owner's Manual (PDF) - Page 131
Service-Only Procedure on or Peripheral Interposer Board
View all Dell PowerEdge R905 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 131 highlights
Figure 3-33. Removing and Installing a Fan Interposer Board 2 1 3 4 1 screws (2) 3 tabs (2) 2 fan interposer board 4 slots (2) Installing a Fan Interposer Board 1 Slip the two securing tabs on the fan interposer board into the two slots on the side of the fan bay. See Figure 3-33. 2 Secure the fan interposer board with the two screws. 3 Replace the SAS backplane (systems with 3.5" hard drives) or peripheral interposer board (systems with 2.5" hard drives). See "SAS Backplane (Service-Only Procedure)" on page 122 or "Peripheral Interposer Board" on page 126. 4 Install the fans. See "Replacing a Cooling Fan" on page 68. Installing System Components 131
Installing System Components
131
Figure 3-33.
Removing and Installing a Fan Interposer Board
Installing a Fan Interposer Board
1
Slip the two securing tabs on the fan interposer board into the two slots on
the side of the fan bay. See Figure 3-33.
2
Secure the fan interposer board with the two screws.
3
Replace the SAS backplane (systems with 3.5" hard drives) or peripheral
interposer board (systems with 2.5" hard drives). See "SAS Backplane
(Service-Only Procedure)" on page 122 or "Peripheral Interposer Board" on
page 126.
4
Install the fans. See "Replacing a Cooling Fan" on page 68.
1
screws (2)
2
fan interposer board
3
tabs (2)
4
slots (2)
2
4
3
1