Dell PowerEdge R905 Hardware Owner's Manual (PDF) - Page 24
The LCD continues, BMC Management Utility. - servers
View all Dell PowerEdge R905 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Table 1-7. LCD Status Messages (continued) Line 1 Line 2 Message Message E1313 Fan Redundancy Causes Corrective Actions One or more cooling fans See "Troubleshooting has failed. Cooling fan System Cooling redundancy has been lost. Problems" on page 155. E1414 CPU # Thermtrip E1418 CPU # Presence Specified microprocessor is out of acceptable temperature range and has halted operation. See "Troubleshooting System Cooling Problems" on page 155. If the problem persists, ensure that the microprocessor heat sinks are properly installed. See "Troubleshooting the Microprocessors" on page 165. NOTE: The LCD continues to display this message until the system's power cord is disconnected and reconnected to the AC power source, or the SEL is cleared using either Server Assistant or the BMC Management Utility. See the Dell OpenManage Baseboard Management Controller User's Guide for information about these utilities. Specified processor is missing or bad, or the system is in an unsupported configuration. See "Troubleshooting the Microprocessors" on page 165. 24 About Your System