Dell PowerEdge R905 Hardware Owner's Manual (PDF) - Page 39
Remote Access, Expansion Cards
View all Dell PowerEdge R905 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Table 1-8. System Messages (continued) Message Causes Corrective Actions Read fault Requested sector not found The operating system Replace the diskette. cannot read from the hard Ensure that the diskette drive, the system could and hard drive cables are not find a particular properly connected. See sector on the disk, or the "Troubleshooting an requested sector is Optical Drive" on page 158, defective. or "Troubleshooting a Hard Drive" on page 159 for the appropriate drive(s) installed in your system. Remote Access Controller cable error or incorrect card in the RAC slot. RAC cables are not Check that the RAC cables connected, or RAC card is are connected, and that the installed in the wrong RAC card is installed in the expansion slot. correct expansion slot. See "RAC Card" on page 83. Remote Access Controller not installed in the RAC slot. RAC card is installed in Check that the RAC card is the wrong expansion slot. installed in the correct expansion slot. See "RAC Card" on page 83. Remote configuration update attempt failed System unable to process Retry Remote Remote Configuration Configuration. request. ROM bad checksum = address An expansion card is improperly installed or is faulty. Reseat the expansion cards. Ensure that all appropriate cables are securely connected to the expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 164. Sector not found Faulty hard drive. Seek error See "Troubleshooting a Hard Drive" on page 159. Seek operation failed About Your System 39