Dell PowerEdge R905 Hardware Owner's Manual (PDF) - Page 36
Invalid PCIe card, Internal Storage
View all Dell PowerEdge R905 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Table 1-8. System Messages (continued) Message Causes Corrective Actions Invalid NVRAM configuration, Resource Reallocated System detected and corrected a resource conflict. No action is required. Invalid PCIe card found in the Internal Storage slot! The system halted Remove the PCIe because an invalid PCIe expansion card and install a expansion card is installed SAS controller in the in the dedicated storage dedicated slot. controller slot. Keyboard Faulty keyboard See "Getting Help" on Controller failure controller; faulty system page 179. board Manufacturing mode System is in detected manufacturing mode. Reboot to take the system out of manufacturing mode. Memory address line failure at address, read value expecting value Faulty or improperly installed memory modules. See "Troubleshooting System Memory" on page 156. Memory double word logic failure at address, read value expecting value Memory odd/even logic failure at address, read value expecting value Memory write/read failure at address, read value expecting value 36 About Your System