Dell PowerEdge R905 Hardware Owner's Manual (PDF) - Page 30
E201F, DRAC Config, CPU Config, Memory, Population, POST Fail, SBE Log, Disable DIMM
View all Dell PowerEdge R905 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Table 1-7. LCD Status Messages (continued) Line 1 Line 2 Message Message Causes Corrective Actions E201F DRAC Config Remote access controller (RAC) configuration failure. Check screen for specific error messages. Ensure that the RAC card and cables are properly seated. See "RAC Card" on page 83. If problem persists, see your RAC documentation. E2020 CPU Config CPU configuration failure. Check screen for specific error messages. E2021 Memory Population Incorrect memory configuration. Memory population order incorrect. Check screen for specific error messages. See "Troubleshooting System Memory" on page 156. E2022 POST Fail General failure after video. Check screen for specific error messages. E2110 MBE DIMM ## & ## One of the DIMMs in the See "Troubleshooting set implicated by "## & System Memory" on ##" has had a memory page 156. multi-bit error (MBE). E2111 SBE Log Disable DIMM ## The system BIOS has See "Troubleshooting disabled memory single- System Memory" on bit error (SBE) logging, page 156. and will not resume logging further SBEs until the system is rebooted. "##" represents the DIMM implicated by the BIOS. 30 About Your System