Dell PowerEdge R905 Hardware Owner's Manual (PDF) - Page 30

E201F, DRAC Config, CPU Config, Memory, Population, POST Fail, SBE Log, Disable DIMM

Page 30 highlights

Table 1-7. LCD Status Messages (continued) Line 1 Line 2 Message Message Causes Corrective Actions E201F DRAC Config Remote access controller (RAC) configuration failure. Check screen for specific error messages. Ensure that the RAC card and cables are properly seated. See "RAC Card" on page 83. If problem persists, see your RAC documentation. E2020 CPU Config CPU configuration failure. Check screen for specific error messages. E2021 Memory Population Incorrect memory configuration. Memory population order incorrect. Check screen for specific error messages. See "Troubleshooting System Memory" on page 156. E2022 POST Fail General failure after video. Check screen for specific error messages. E2110 MBE DIMM ## & ## One of the DIMMs in the See "Troubleshooting set implicated by "## & System Memory" on ##" has had a memory page 156. multi-bit error (MBE). E2111 SBE Log Disable DIMM ## The system BIOS has See "Troubleshooting disabled memory single- System Memory" on bit error (SBE) logging, page 156. and will not resume logging further SBEs until the system is rebooted. "##" represents the DIMM implicated by the BIOS. 30 About Your System

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198

30
About Your System
E201F
DRAC Config
Remote access controller
(RAC) configuration
failure.
Check screen for specific
error messages. Ensure
that the RAC card and
cables are properly seated.
See "RAC Card" on
page 83. If problem
persists, see your RAC
documentation.
E2020
CPU Config
CPU configuration
failure.
Check screen for specific
error messages.
E2021
Memory
Population
Incorrect memory
configuration. Memory
population order
incorrect.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 156.
E2022
POST Fail
General failure after
video.
Check screen for specific
error messages.
E2110
MBE DIMM ##
& ##
One of the DIMMs in the
set implicated by "## &
##" has had a memory
multi-bit error (MBE).
See "Troubleshooting
System Memory" on
page 156.
E2111
SBE Log
Disable DIMM
##
The system BIOS has
disabled memory single-
bit error (SBE) logging,
and will not resume
logging further SBEs until
the system is rebooted.
"##" represents the
DIMM implicated by the
BIOS.
See "Troubleshooting
System Memory" on
page 156.
Table 1-7.
LCD Status Messages
(continued)
Line 1
Message
Line 2
Message
Causes
Corrective Actions