Table 5-18 POST error messages (continued) Screen message Probable cause Recommended action 207-Incompatible memory modules detected Single-bit ECC error. 1. Verify the memory module type. 2. Insert the DIMM in another memory socket. 3. Replace the memory module if the problem persists. 208-Two-DIMM configurations use slots one and five DIMMs are loaded in incorrect slots for Verify that the two DIMMs are installed in slots one and a two-DIMM configuration. five only. 209-Incompatible memory (FBDs) detected Incorrect memory module type in use. Verify that the memory modules are compatible with workstation requirements. 210-Mismatched memory (AMBs) detected Different memory module types are matched. Verify that compatible memory module types are used in matched pairs. 211-Memory warning condition detected Improper or defective memory module. Replace the memory module. 212-Failed Processor Processor has failed to initialize. 1. Reseat the processor in its socket. 2. If the processor does not respond, replace it. 213-Incompatible Memory Modules A memory module in the memory 1. Verify the memory module type. socket identified in the error message is missing critical SPD information, or 2. Insert the DIMM in another memory socket. is incompatible with the chipset. 3. Replace the module with a DIM conforming to the SPD standard. 214-DIMM Configuration Warning DIMMs are not installed correctly (not See the service label on the workstation access panel paired correctly). for the correct memory configurations, and reseat the DIMMs accordingly. 216-Memory Size Exceeds Maximum Supported The amount of memory installed exceeds that supported by the hardware. 1. Verify how much memory your system supports. 2. Remove the excess memory. 301-Keyboard Error Keyboard failure. 1. Reconnect the keyboard with the workstation powered off. 2. Check the connector for bent or missing pins. 3. Be sure that none of the keys are pressed. 4. Replace the keyboard. 303-Keyboard Controller Error I/O board keyboard controller is defective or is not set properly. 1. Reconnect the keyboard with the workstation powered off. 2. Replace the system board. 304-Keyboard or System Unit Error Keyboard failure. 1. Reconnect the keyboard with the workstation powered off. 2. Be sure that none of the keys are pressed. 3. Replace keyboard. 4. Replace system board. 510-Splash Screen image corrupted Splash Screen image has errors. Update system BIOS. 140 Chapter 5 System diagnostics and troubleshooting ENWW