HP xw8600 HP xw8600 Workstation Service and Technical Reference Guide - Page 151
POST error messages, continued, Screen message, Probable cause, Recommended action
View all HP xw8600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 151 highlights
Table 5-18 POST error messages (continued) Screen message Probable cause Recommended action 511-CPU. CPU A, or CPU B Fan is not connected or is defective. Fan not detected 1. Reseat the fan cable. 2. Reseat the fan. 3. Replace the fan. 512-Chassis, rear chassis, or Fan is not connected or it might be front chassis fan not detected defective. 1. Reseat the chassis, rear chassis, or front chassis fan cable. 2. Reseat the chassis, rear chassis, or front chassis fan. 3. Replace the chassis, rear chassis, or front chassis fan. 513-Memory fan not detected Missing or disconnected memory fan. 1. Ensure the memory fan is installed. 2. Ensure proper memory fan connections. 514-CPU or Chassis Fan not CPU or chassis fan is missing, is not 1. Verify that the processor or chassis fan is installed detected connected, or is defective. and connected properly. 2. Replace the processor fan or the chassis fan. 515-CPU Overtemp ocurrred Insufficient processor cooling or processor defect. 1. If necessary, add a heatsink to the processor and ensure proper operation. 516-PCI fan not detected Missing PCI fan or disconnected fan cable. 2. Replace the processor. ● Add a PCI fan if necessary. ● Verify proper PCI fan cable connection and operation. 517-Low power CPU heatsink(s) detected for high power CPUs 518-Power supply wattage insufficient for hardware configuration Inadequate heatsink is installed. Replace the low power heatsink with a high power heatsink. Workstation configuration requires ● more power than the power supply can provide. ● Reduce the workstation power consumption. Replace the power supply with a high output power supply. 601-Diskette Controller Error Diskette controller circuitry or diskette 1. Run the Computer Setup (F10) utility. drive circuitry incorrect. 2. Verify cabling and replace defective cables if necessary. 3. Clear CMOS. 4. Replace the diskette drive. 5. Replace the system board. 605-Diskette Drive Type Error Mismatch in drive type. 1. Run the Computer Setup (F10) Utility. 2. Disconnect any other diskette controller devices (tape drives). 3. Clear the CMOS. 610-External Storage Device External storage device is not 1. Verify that the external device is present and Failure detected, is improperly connected, or connected properly. is defective. 2. Replace the external device. ENWW POST error messages 141