HP xw8600 HP xw8600 Workstation Service and Technical Reference Guide - Page 152
Screen message, Probable cause, Recommended action, Run the Drive Protection System test if - firmware
View all HP xw8600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 152 highlights
Table 5-18 POST error messages (continued) Screen message Probable cause 912-Computer Cover Has N/A Been Removed Since Last System Start Up 914- Hood Lock Coil is not Connected Mechanism is missing or is not connected. 917-Front Audio Not Connected Mechanism is missing or is not connected. 918-Front USB Not Connected Mechanism is missing or is not connected. 919-Multi-Bay Riser Not Connected Mechanism is missing or is not connected. 921-Device in PCI Express Missing, improperly seated, or Slot failed to initialize defective card. Recommended action No action required. 1. Reconnect or replace the missing mechanism. 2. Reseat or replace the missing mechanism cable. 1. Reconnect or replace the missing mechanism. 2. Reseat or replace the missing mechanism cable. 1. Reconnect or replace the missing mechanism. 2. Reseat or replace the missing mechanism cable. 1. Reconnect or replace the missing mechanism. 2. Reseat or replace the missing mechanism cable. 1. Verify that the card is installed. 2. Reseat the card. 3. Replace the card. 922-Fatal error in slot # Fatal error occurred in the designated Move the card to a different slot. If the problem persists, slot. replace the card. 923-Non fatal uncorrectable A PCI or PCIe nonfatal error occurred Move the card to a different slot. If the problem persists, PCI error in slot # for the card in the designated slot. replace the card. 924-Non fatal correctable PCI error A PCI or PCIe nonfatal error occurred Contact HP support. for the card in the designated slot. 925-Non fatal uncorrectable Nonfatal, uncorrectable ESI error on Contact HP support. ESI error slot # occurred. 926-Non fatal correctable ESI error Nonfatal, correctable ESI error on slot Contact HP support. # occurred. 927-Non fatal FSB error Nonfatal FSB error on FSB # occurred. Contact HP support. 928-Non fatal uncorrectable Nonfatal, uncorrectable FBD error on Contact HP support. FBD error DIMM # occurred. 929-Non fatal correctable FBD error Nonfatal, correctable FBD error on (DIMM is identified). Contact HP support. 930-Non fatal internal Northbridge error Nonfatal, Internal Northbridge error. Contact HP support. 1720-SMART Hard Drive Detect Imminent Failure Hard drive is about to fail. (Some hard 1. drives have a firmware patch that fixes erroneous error messages.) 2. Determine if the hard drive is giving a correct error message. Run the Drive Protection System test (if applicable). 3. Apply firmware patch (if applicable). See http://www.hp.com/support. 4. Back up contents and replace the hard drive. 1783-Fixed Disk 0/1 locked Hard disk drive failure. Diagnose the hard drive, and replace it if necessary. 142 Chapter 5 System diagnostics and troubleshooting ENWW