Sony XDSPD2000 User Manual (XDS-PD1000 and XDS-PD2000 Operation Manual for Fir - Page 110

H to 16H

Page 110 highlights

Menu items in the 600s, relating to the timecode, metadata, and UMID Item number Item name Settings 601 VITC POSITION In 59.94i/59.94P/ Select the line into which to insert VITC signals (SD output) SEL-1 a) 29.97P mode 12H to 16H to 20H: Any line from line 12 through line 20. In 50i/50P/25P mode Notes • You can insert VITC signals in two places. To insert in two places, set both item 601 and item 602. • In 59.94i/59.94P/29.97P mode (J), output of wide picture information is given priority if OUTPUT in setup menu item 731 is set to "auto" and the VITC insertion line is set to line 16. • In 59.94i/59.94P/29.97P mode (UC), output of wide picture information is given priority if OUTPUT in setup menu item 731 is set to "auto" and the VITC insertion line is set to line 20. Select the line into which to insert VITC signals (SD output) 9H to 19H to 22H: Any line from line 9 through line 22. Note You can insert VITC signals in two places. To insert in two places, set both item 601 and item 602. 602 VITC POSITION In 59.94i/59.94P/ Select the line into which to insert VITC signals (SD output) SEL-2 a) 29.97P mode 12H to 18H to 20H: Any line from line 12 through line 20. In 50i/50P/25P mode Notes • You can insert VITC signals in two places. To insert in two places, set both item 601 and item 602. • In 59.94i/59.94P/29.97P mode (J), output of wide picture information is given priority if OUTPUT in setup menu item 731 is set to "auto" and the VITC insertion line is set to line 16. • In 59.94i/59.94P/29.97P mode (UC), output of wide picture information is given priority if OUTPUT in setup menu item 731 is set to "auto" and the VITC insertion line is set to line 20. Select the line into which to insert VITC signals (SD output) 9H to 21H to 22H: Any line from line 9 through line 22. Note You can insert VITC signals in two places. To insert in two places, set both item 601 and item 602. 605 TCG REGEN MODE Select the signal to be regenerated when the timecode generator is in the regeneration mode. TC&UB: Both the timecode and user bits are regenerated. TC: Only the timecode is regenerated. UB: Only the user bits are regenerated. 607 U-BIT BINARY GROUP FLAG Select the user bits to be used in the timecode generated by the timecode generator. 000:not specified [000]: Character set not specified. 001:iso character [001]: 8-bit characters compliant with ISO 646 and ISO 2022. 010:unassigned-1 [010]: Undefined. 011:unassigned-2 [011]: Undefined. 100:unassigned-3 [100]: Undefined. 101:page / line [101]: SMPTE-262M page/line multiplex system. 110:unassigned-4 [110]: Undefined. 111:unassigned-5 [111]: Undefined. 610 REGEN CONTROL MODE b) Select whether the time code is automatically regenerated. manual [manu]: The time code generator operates in accordance with the TCG and PRST/RGN settings in the P4 TC page of the function menu, regardless of whether the unit is acting as recorder or player. assemble & insert [full]: When this unit is editing as a recorder, the time code generator follows the time code played back from internal storage. Chapter 7 Menus 110 Setup Menu

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161

110
Setup Menu
Chapter 7
Menus
Menu items in the 600s, relating to the timecode, metadata, and UMID
Item number
Item name
Settings
601
VITC POSITION
SEL-1
a)
In 59.94i/59.94P/
29.97P mode
Select the line into which to insert VITC signals (SD output)
12H to 16H
to 20H:
Any line from line 12 through line 20.
Notes
You can insert VITC signals in two places. To insert in two places, set
both item 601 and item 602.
In 59.94i/59.94P/29.97P mode (J), output of wide picture information is
given priority if OUTPUT in setup menu item 731 is set to “auto” and the
VITC insertion line is set to line 16.
In 59.94i/59.94P/29.97P mode (UC), output of wide picture information
is given priority if OUTPUT in setup menu item 731 is set to “auto” and
the VITC insertion line is set to line 20.
In 50i/50P/25P
mode
Select the line into which to insert VITC signals (SD output)
9H to 19H
to 22H:
Any line from line 9 through line 22.
Note
You can insert VITC signals in two places. To insert in two places, set
both item 601 and item 602.
602
VITC POSITION
SEL-2
a)
In 59.94i/59.94P/
29.97P mode
Select the line into which to insert VITC signals (SD output)
12H to 18H
to 20H:
Any line from line 12 through line 20.
Notes
You can insert VITC signals in two places. To insert in two places, set
both item 601 and item 602.
In 59.94i/59.94P/29.97P mode (J), output of wide picture information is
given priority if OUTPUT in setup menu item 731 is set to “auto” and the
VITC insertion line is set to line 16.
In 59.94i/59.94P/29.97P mode (UC), output of wide picture information
is given priority if OUTPUT in setup menu item 731 is set to “auto” and
the VITC insertion line is set to line 20.
In 50i/50P/25P
mode
Select the line into which to insert VITC signals (SD output)
9H to 21H
to 22H:
Any line from line 9 through line 22.
Note
You can insert VITC signals in two places. To insert in two places, set
both item 601 and item 602.
605
TCG REGEN MODE
Select the signal to be regenerated when the timecode generator is in the
regeneration mode.
TC&UB
: Both the timecode and user bits are regenerated.
TC
: Only the timecode is regenerated.
UB
: Only the user bits are regenerated.
607
U-BIT BINARY GROUP FLAG
Select the user bits to be used in the timecode generated by the
timecode generator.
000:not specified [000]
: Character set not specified.
001:iso character [001]
: 8-bit characters compliant with ISO 646 and
ISO 2022.
010:unassigned-1 [010]
: Undefined.
011:unassigned-2 [011]
: Undefined.
100:unassigned-3 [100]
: Undefined.
101:page / line [101]
: SMPTE-262M page/line multiplex system.
110:unassigned-4 [110]
: Undefined.
111:unassigned-5 [111]
: Undefined.
610
REGEN CONTROL MODE
b)
Select whether the time code is automatically regenerated.
manual [manu]
:
The time code generator operates in accordance with
the TCG and PRST/RGN settings in the P4 TC page of the function
menu, regardless of whether the unit is acting as recorder or player.
assemble & insert [full]:
When this unit is editing as a recorder, the time
code generator follows the time code played back from internal
storage.