Sony XDSPD2000 User Manual (XDS-PD1000 and XDS-PD2000 Operation Manual for Fir - Page 131

Periodic Maintenance, Operating hours meter

Page 131 highlights

Periodic Maintenance Operating hours meter The operating hours meter can provide six items of information about the operational history of the unit. The information can be displayed in the status display area and also, by text superimposition, on the video monitor screen or PC monitor connected to the MONITOR connector. Use the information as a guide in scheduling periodic maintenance. For periodic maintenance, contact your Sony service or sales representative. To display the operating hours meter Press the MENU button to display the setup menu, then turn the PUSH SET knob to display the required item (H11 to H15). To reset the display of the operating hours meter Select the item you want to reset with the menu item M36: HOURS METER RESET, and press the PUSH SET knob. To exit from the operating hours meter Press the RETURN function button (F1) to return to the setup menu. Press the EXIT function button (F6) to return to the screen that was displayed before you entered the setup menu. Display modes of the operating hours meter H01: OPERATION HOURS mode Displays the total number of hours the unit has been powered on in units of 1 hour. H02: LASER PARAMETER 0 mode (not resettable) Of the two optical heads, this shows a counter of the cumulative light output time by one optical head in units of hours. 1) This can be used as a guide in determining when to replace the optical head. 1) The counter advances at different rates during recording and playback. It is also affected by the ambient temperature. H11: OPERATION HOURS mode (resettable) Same as H01 except that the count is resettable. This can be used as a guide in determining when to replace parts. H13: SEEK RUNNING HOURS 0 mode (resettable) Of the two optical heads, this shows the cumulative seek operation time for one optical head in units of hours. The count is resettable. This can be used as a guide in determining when to replace the seek motor. H14: SPINDLE RUNNING HOURS mode (resettable) This shows the cumulative spindle rotation time, in units of hours. The count is resettable. This can be used as a guide in determining when to replace the spindle motor. H15: LOADING COUNTER mode (resettable) Display the total number of times disc has been loaded in the unit. The count is resettable. Appendix 131 Periodic Maintenance

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161

131
Periodic Maintenance
Appendix
Periodic Maintenance
Operating hours meter
The operating hours meter can provide six items of
information about the operational history of the unit. The
information can be displayed in the status display area and
also, by text superimposition, on the video monitor screen
or PC monitor connected to the MONITOR connector. Use
the information as a guide in scheduling periodic
maintenance.
For periodic maintenance, contact your Sony service or
sales representative.
Display modes of the operating hours
meter
H01: OPERATION HOURS mode
Displays the total number of hours the unit has been
powered on in units of 1 hour.
H02: LASER PARAMETER 0 mode (not
resettable)
Of the two optical heads, this shows a counter of the
cumulative light output time by one optical head in units of
hours.
1)
This can be used as a guide in determining when
to replace the optical head.
1) The counter advances at different rates during recording and playback. It
is also affected by the ambient temperature.
H11: OPERATION HOURS mode (resettable)
Same as H01 except that the count is resettable.
This can be used as a guide in determining when to replace
parts.
H13: SEEK RUNNING HOURS 0 mode (resettable)
Of the two optical heads, this shows the cumulative seek
operation time for one optical head in units of hours.
The count is resettable.
This can be used as a guide in determining when to replace
the seek motor.
H14: SPINDLE RUNNING HOURS mode
(resettable)
This shows the cumulative spindle rotation time, in units of
hours.
The count is resettable.
This can be used as a guide in determining when to replace
the spindle motor.
H15: LOADING COUNTER mode (resettable)
Display the total number of times disc has been loaded in
the unit.
The count is resettable.
To display the operating hours meter
Press the MENU button to display the setup menu, then
turn the PUSH SET knob to display the required item (H11
to H15).
To reset the display of the operating hours
meter
Select the item you want to reset with the menu item M36:
HOURS METER RESET, and press the PUSH SET knob.
To exit from the operating hours meter
Press the RETURN function button (F1) to return to the
setup menu.
Press the EXIT function button (F6) to return to the screen