HP NetServer AA 6200 HP NetServer AA 6200 Solution Release 3.0 Messages - Page 217
A serious communication problem between the components
View all HP NetServer AA 6200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 217 highlights
Chapter 13 MtcMon Messages IOPn.MtcMon FRU: IOPx/CEy tuple power supply failure. Variables x - the ID of the IOP whose tuple has lost power y - the ID of the CE whose tuple has lost power Severity Error Description All components in the tuple have lost power. Action • Check the power supply connections to the tuple components. • Make sure that the line voltage being supplied to the tuple components is within operational parameters. IOPn.MtcMon FRU: IOPx CEx tuple processing capability failure. Variables x - the ID of the tuple containing the IOP and CE with the fatal condition Severity Error Description This message is generated when both the CE and IOP in a tuple report a fatal condition. Usually, this is the result of: • A serious communication problem between the components • A secondary fault that occurred in one unit while another one was being handled in the other unit This message encompasses all failures of both the IOP and CE within a single tuple except for power failure. Related Messages IOPn.MtcMon FRU: IOPx tuple power supply failure. Action • Run the MIC Connectivity Test in the MIC BIOS utility between the IOPs and the CEs to ensure that the MIC adapters and the connection between them are functioning correctly. • If the condition persists without indicating any other failed components, contact your service provide for assistance. 207