HP StorageWorks 2/16V Brocade Fabric OS Command Reference Manual - Supporting - Page 162
diagSetBurnin, must be run prior
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 162 highlights
2 diagSetBurnin diagSetBurnin Initializes the blade for a burn-in run. Synopsis diagsetburnin [--slot slotnumber][script | -current] Description This sets up the blade burn-in parameters for the registered burn-in script. The burn-in will start at the next run of power-on self-test (POST) on the designated blade(s). The errors and activity logs are stored in flash memory. The activity log of the script is saved in /var/log/scriptname.slot.log. The errors produced are available from the burninErrShow command on a per-blade basis. When power cycles occur, the burn-in activity is restarted at the test that was interrupted at the time of the power cycle. This command does not require a reboot to take effect. It is advisable to run the burninErrClear command prior to running diagSetBurnin and diagSetCycle. Boards must be installed prior to running this command and diagSetCycle must be run prior to diagSetBurnin if you want to use both commands. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: --slot slotnumber Specify which slot number to update. If this option is not specified at all, then all slots on the switch are set up for burn-in. script Specify the name of the burn-in script to run. -current Set the name of burn-in script to current burn-in script. Examples To set the burn-in script and mode: switch:admin> diagsetburnin --slot 1 -current existing script is: /fabos/share/switchess.sh Burnin mode is Enabled. Removing all log files in /var/log for slot 1 Slot 1 burnin name is now /fabos/share/switchess.sh Config update Succeeded See Also burninErrShow, diagSetCycle 130 Fabric OS Command Reference Manual 53-1000436-01