HP StorageWorks 2/16V Brocade Fabric OS Command Reference Manual - Supporting - Page 659
accessControl Configuration Parameters, mibCapability Configuration Parameters, MIBs on or off.
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 659 highlights
snmpConfig 2 Note that in order for an SNMP management station to receive SNMPv3 traps generated by the agent, the administrator must configure a trap recipient value to correspond to the IP address of the management station. Also, in addition the trap recipient should be able to pass the ACL check as described in accessControl section. The trap recipient value should be associated with one of the six users of SNMPv3 and trap severity level. Note that the factory default value for the SNMPv3 trap recipient of each user is '0.0.0.0'. accessControl Configuration Parameters The ACL check is as follows: there are six ACLs to restrict SNMP get/set/trap operations to hosts under a host-subnet-area. Host-subnet-area is defined by comparing nonzero IP octets. For example, an ACL of 192.168.64.0 enables access by any hosts that start with the specified octets. The connecting host is enabled to set each host-subnet-area to be read-write or read-only. The highest privilege matched out of six entries is given to the access. The ACL check is turned off when all six entries contain 0.0.0.0. The default values of all six entries are 0.0.0.0. NOTE When secure mode is enabled, the Access Control List feature is incorporated into the WSNMP and RSNMP security policies. mibCapability Configuration Parameters This mibCapability option a turns on or off certain MIBS and TRAPS. The agtCfgDefault also resets the SNMP MIB and Trap Capability to default with other SNMP agent configuration. If SNMP MIB is disabled, then corresponding traps also are disabled. If any trap group is disabled, then corresponding individual traps also are disabled. The FE and SW MIBs are always accessible. snmpMibCapSet does not prompt you to turn these MIBs on or off. FA-MIB Specifying yes means the user can access FA-MIB variables with an SNMP manager. The default value is yes. FICON-MIB Specifying yes means the user can access FICON-MIB variables with an SNMP manager. The default value is yes. HA-MIB Specifying yes means the user can access Entity-MIB and HA-MIB variables with an SNMP manager. The default value is yes. SW-TRAP Specifying yes means the SNMP management application can receive SW-TRAPS from the switch. The default value is yes. Users can also turn on or off individual SW Traps. The individual SW traps are swFCPortScn, swEventTrap, swFabricWatchTrap and swTrackChangesTrap. FA-TRAP Specifying yes means the SNMP management application can receive FA-TRAPS from the switch. The default value is yes. Users can also turn on or off individual FA Traps. The individual FA Traps are connUnitStatusChange, connUnitEventTrap, connUnitSensorStatusChange and connUnitPortStatusChange. SW-EXTTRAP Specifying yes means user can receive SSN in the SW traps. The default value is 'no'. Fabric OS Command Reference Manual 627 53-1000436-01