systemVerification, To initiate a system verification test on all switches in the fabric, Examples
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 728 highlights
2 systemVerification Examples To initiate a system verification test on all switches in the fabric: switch:admin> systemverification -short systemverification: Setting parameters for short run. systemverification: burnin parameters. CURRENT - KEYWORD : DEFAULT 1 - number_of_runs : 1 2 - vib : 2 10 - thermal : 10 SYSTEMVERIFICATION - label : BURNIN 2 - min_lb_mode : 2 1 - tbr_passes : 1 1 - prt_on : 1 1 - cntmem_on : 1 1 - cmi_on : 1 1 - retention_on : 1 1 - cam_on : 1 1 - flt_passes : 50 1 - sta_passes : 25 1 - plb_nframes : 100 1 - txd_nframes : 50 1 - xpt_nframes : 200 1 - bpt_nframes : 20 1 - slk_nmegs : 50 1 - bpt_all_nframes : 30 1 - slk_all_nmegs : 50 systemverification: Arming the burnin run on switch 0. systemverification: Starting burnin on Switch 0 systemverification: Monitoring progress of the burnin activity. systemverification: Outputting Status State Status Run Cmd TotCmds Script COMPLETED PASS 1 22 22 switchburnin.sh See Also burninErrShow, burninStatus, diagSetBurnin, diagSetCycle 696 Fabric OS Command Reference Manual 53-1000436-01