HP StorageWorks 2/16V Brocade Fabric OS Command Reference Manual - Supporting - Page 746
txdPath, At each pass
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 746 highlights
2 txdPath txdPath Performs a functional test of ASIC pair TXA,TXD connections. Synopsis txdpath [--slot slotnumber][-nframes count][-lb_mode mode][-spd_mode mode][-nonstop mode] [-ports itemlist] Description Use this command to verify the TXA, TXD, and CMI data paths between the chips within a mini-switch. This is done by configuring all of the ports on the mini-switch in internal loopback and sending a frame from each quadrant to each other port on the same mini-switch. The frame starts from the CPU and is transmitted by the first port which also receives the frame and deposits it in central memory. The second port then reads the frame from central memory using its own TXA,TXD path. The frame is then looped back one more time and is sent back to the CPU, where it is compared with the transmitted data. Only one frame is transmitted and received at any one time. External cable is not required to run this test. The port LEDs flicker green rapidly while the test is running. The test method is as follows: Set all ports present for parallel loopback. Then, for each pair of source quadrants and destination ports: Set up a source port to route frames to a destination port and a destination port to route frames to the CPU. Transmit frame F through the source port. Pick up the frame from the destination port. Check if any of the eight statistic error counters are not 0: ENC_in, CRC_err, TruncFrm, FrmTooLong, BadEOF, Enc_out, BadOrdSet, DiscC3 Repeat steps 2 through 5 for all ports present until either the number of frames (or -nmegs count) requested is reached, or, all ports are marked bad. At each pass, a different data type is used to create the frame from a palette of seven; meaning if a pass of seven is requested, seven different frames are used in the test. If eight passes, the first seven frames are unique, and the eighth is the same as the first. The data palette of seven are: CSPAT: 0x7e, 0x7e, 0x7e, 0x7e, ... BYTE_LFSR: 0x69, 0x01, 0x02, 0x05, ... CHALF_SQ: 0x4a, 0x4a, 0x4a, 0x4a, ... QUAD_NOT: 0x00, 0xff, 0x00, 0xff, ... CQTR_SQ: 0x78, 0x78, 0x78, 0x78, ... CRPAT: 0xbc, 0xbc, 0x23, 0x47, ... RANDOM: 0x25, 0x7f, 0x6e, 0x9a, ... If seven passes are requested, the seven different data types are used in the test. If eight passes are requested, the first seven frames use unique data type. This command is supported only on Brocade 200E,3250, 3850, 3900,4100, 24000, and 48000 platforms; use portLoopbackTest or miniCycle instead. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: 714 Fabric OS Command Reference Manual 53-1000436-01