/1870N, SERVICE, MANUAL, Position, smudge, interval, sample, Photosensitive
UPC - 012502603900
View all Brother International HL 1850 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 214 highlights
HL-1850/1870N SERVICE MANUAL NOTE: Clean the drum unit as follows: (1) Remove the toner cartridge from the drum unit. Place the printing samples in front of the drum unit, and find the exact position of the image defect. Drum unit Position of smudge on the drum 94mm interval Printing sample Fig. 6-31 (2) Turn the drum gear by hand while looking at the surface of the photosensitive drum. -e- Photosensitive drum Q Fig. 6-32 (3) Wipe the surface of the photosensitive drum with a cotton swab until the dust or paper powder on the surface comes off. Photosensitive drum a Fig. 6-33 CAUTION: • Do not wipe the surface of the photosensitive drum with something sharp. (ball-point pen etc.) • Use cleaning liquid which is a 50-50 mixture ofethyl alcohol andpure water. 6-47