Xerox 6180N Using LCDS Print Description Language - Page 131
Dbcode Assign
UPC - 095205425307
View all Xerox 6180N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 131 highlights
Specifying input parameters ac identifier A command identifier of the type ac is optional for the first DBCODE command within a JDE. Thereafter, each additional DBCODE command must include the identifier. The ac identifier consists of 1 to 6 alphanumeric characters (A through Z and 0 through 9). One of the characters must be alphabetic. DBCODE command parameters The following table summarizes the DBCODE command parameters. Table 2-19. Summary of DBCODE command parameters Parameter DBCODE ASSIGN DBCODE DEFAULT Specifies Online Offline DJDE Defines user double-byte code assignments. Y N N Specifies a base code from which double-byte Y character code assignment exceptions can be made. N N The following sections describe the syntax of the DBCODE command parameters and explain the parameter options. DBCODE ASSIGN Defines double-byte character code assignment exceptions or an entire user character translation table. Syntax ac: DBCODE ASSIGN = {(input, output) | (input, (output1 [, output2] [,...])} Options Table 2-20. DBCODE ASSIGN parameter options and definitions Option Definition input A numeric constant that defines the input double-byte code. output A numeric constant that defines the output double-byte code that corresponds to the input code Default No default Using LCDS Print Description Language 2-23