Xerox 6180N Using LCDS Print Description Language - Page 173
Volume Maxlab
UPC - 095205425307
View all Xerox 6180N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 173 highlights
Specifying input parameters Options Table 2-69. VOLUME LPACK parameter options and definitions Option Definition NO Indicates that no unpacking operation will be performed. YES Indicates that the labels are packed. If YES is specified, the UNPACK parameters specify the required unpacking method for both the labels and the input data. If the data in a report is packed, the labels may be either packed or unpacked. Default NO VOLUME MAXLAB Specifies the longest physical block that will be treated as a label when an undefined label is specified (LABEL=UNDEF). Syntax VOLUME MAXLAB = value Options Table 2-70. MAXLAB parameter options and definitions Option Definition value Specifies in bytes the maximum length of the longest physical block. The value can range from 2 to 4096 bytes. The specified value must be greater than the MINLAB value and must not exceed the BLOCK LENGTH. Default 81 VOLUME MAXLAB parameter: point to note Any data block whose length is between MINLAB and MAXLAB (inclusive) is treated as a label. VOLUME MINLAB Specifies the smallest physical block that will be treated as a label when an undefined label is specified (LABEL=UNDEF). Syntax VOLUME MINLAB = value Using LCDS Print Description Language 2-65