Xerox 6180N Using LCDS Print Description Language - Page 225
R When
UPC - 095205425307
View all Xerox 6180N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 225 highlights
Using logical processing RPAGE TEST Defines the test expression for detection of an RPAGE record that will cause the logical page to be repositioned on a physical page. Syntax RPAGE TEST = testexp Options Table 3-34. RPAGE TEST parameter options and definitions Option Definition testexp test expression. Specifies the criteria test that, if met, will reposition the logical page. The logical page on which this record normally appears is called the "current logical page." Refer to "Coding a test expression" earlier in this chapter for the format and syntax of a test expression. Default No default RPAGE WHEN Defines the portion of the current logical page that will be positioned to the first logical page of a new location. Syntax RPAGE WHEN = {TOP | BOTTOM | NOW} Options Table 3-35. RPAGE WHEN parameter options and definitions Option Definition BOTTOM The logical page following the current logical page is repositioned. NOW The current record is repositioned. This record prints at TOF. Any spacing or skipping defined to occur before printing the current record is ignored. TOP The current logical page is repositioned. Default TOP Using LCDS Print Description Language 3-45