Xerox 6180N Using LCDS Print Description Language - Page 146
Record Length
UPC - 095205425307
View all Xerox 6180N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 146 highlights
Specifying input parameters Options Table 2-40. RECORD FORMAT parameter options and definitions Option Definition type The following types are available for the record format: • BIN (binary) • DEC (decimal) • PACK (packed with no sign) • PKSG (packed with sign) Default BIN RECORD LENGTH Specifies the length of the longest record. Syntax RECORD LENGTH = value Options Table 2-41. RECORD LENGTH parameter options and definitions Option Definition value Specifies in bytes the length of the longest logical record. The value is an integer from 12 to 12288 for the FreeFlow Print Server LCDS systems. Default Online: 150 Offline: 133 RECORD LENGTH parameter: points to note • When you change the LINE DATA parameter to a value greater than the default value, you must also change the RECORD LENGTH parameter accordingly. Otherwise, the data is truncated to the length that was specified in the initial JDL. • You cannot use print position indexing for online processing if you specify a LENGTH greater than 150. 2-38 Using LCDS Print Description Language