Xerox 6180N Using LCDS Print Description Language - Page 171
Volume Kcode
UPC - 095205425307
View all Xerox 6180N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 171 highlights
Specifying input parameters VOLUME KCODE Specifies which double-byte character code translation table the system will use to interpret the input data. Syntax VOLUME KCODE = {keyword | id } Options Table 2-66. VOLUME KCODE parameter options and definitions Option Definition keyword Specifies a specific, standard, system defined double-byte code translation table. The available options are: • IBM: IBM Nihongo character set (Kanji double-byte character sets) • IBMCHN: IBM 5550 code translation table • JEF: Fujitsu JEF Kanji double-byte character set • KEIS: Hitachi KEIS Kanji double-byte character set • UCS2: ISO/IEC 10646 UCS2 character set • USER: Refers to the single unlabeled KCODE command defined within the JDL or JDE. id Specifies an identifier label that was used in a previously defined KCODE command to refer to a specific, user-defined code translation table. The id label is required when multiple KCODE commands are contained within the JDL. Default No default VOLUME LABEL Specifies the type of label on the input tape. Syntax VOLUME LABEL = label type Options Table 2-67. VOLUME LABEL parameter options and definitions Option Definition label-type Specifies the type of label that the tape contains. The following types may be specified: • COBOL (Honeywell 2000 COBOL tape with 120-byte labels) • NONE (the input tape is unlabeled) • ANSI/XEROX ANSI • SPR (Honeywell 2000 System Print Tape) • STANDARD • UNDEF (Input tape label is not defined) Using LCDS Print Description Language 2-63