Yamaha AW16G Owner's Manual - Page 207
Mmc Record Strobe, 13.1.4. Mmc Fast Forward - reviews
View all Yamaha AW16G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 207 highlights
< Reception > If the AW16G is operating as an MMC Slave, the transport will stop when this message is received with a matching device number or a device number of 7F. STATUS ID No. Device ID Command EOX 11110000 F0 System Exclusive Message 01111111 7F Real Time System Exclusive 0ddddddd dd Destination (00-7E, 7F:all call) 00000110 06 Machine Control Command(mcc) sub-id 00000001 01 Stop(MCS) 11110111 F7 End Of Exclusive 5.13.1.2. MMC PLAY < Reception > If the AW16G is operating as an MMC Slave, the transport will begin playback when this message is received with a matching device number or a device number of 7F. STATUS ID No. Device ID Command EOX 11110000 F0 System Exclusive Message 01111111 7F Real Time System Exclusive 0ddddddd dd Destination (00-7E, 7F:all call) 00000110 06 Machine Control Command(mcc) sub-id 00000010 02 Play(MCS) 11110111 F7 End Of Exclusive 5.13.1.3. MMC DEFERED PLAY < Transmission > This message is transmitted with a device number of 7F when the PLAY key is pressed. < Reception > If the AW16G is operating as an MMC Slave, the transport will begin playback when this message is received with a matching device number or a device number of 7F. STATUS ID No. Device ID Command EOX 11110000 F0 System Exclusive Message 01111111 7F Real Time System Exclusive 0ddddddd dd Destination (00-7E, 7F:all call) 00000110 06 Machine Control Command(mcc) sub-id 00000011 03 Deferred play(MCS) 11110111 F7 End Of Exclusive 5.13.1.4. MMC FAST FORWARD < Transmission > This message is transmitted with a device number of 7F when the FF key is pressed or when the Shuttle is rotated toward the right to enter Cue mode. < Reception > If the AW16G is operating as an MMC Slave, the transport will begin fast-forward when this message is received with a matching device number or a device number of 7F. STATUS ID No. Device ID Command EOX 11110000 F0 System Exclusive Message 01111111 7F Real Time System Exclusive 0ddddddd dd Destination (00-7E, 7F:all call) 00000110 06 Machine Control Command(mcc) sub-id 00000110 04 Fast Forward(MCS) 11110111 F7 End Of Exclusive 5.13.1.5. MMC REWIND < Transmission > This message is transmitted with a device number of 7F when the REWIND key is pressed or when the Shuttle is rotated toward the left to enter Review mode. < Reception > If the AW16G is operating as an MMC Slave, the transport will begin rewind when this message is received with a matching device number or a device number of 7F. STATUS ID No. Device ID Command EOX 11110000 F0 System Exclusive Message 01111111 7F Real Time System Exclusive 0ddddddd dd Destination (00-7E, 7F:all call) 00000110 06 Machine Control Command(mcc) sub-id 00000101 05 Rewind(MCS) 11110111 F7 End Of Exclusive 5.13.1.6. MMC RECORD STROBE < Reception > This message is received if the AW16G is operating as an MMC Slave and the device number matches or is 7F. If the transport is stopped, then recording will begin. If the transport is playing, then punch-in will occur. STATUS ID No. Device ID Command EOX 11110000 F0 System Exclusive Message 01111111 7F Real Time System Exclusive 0ddddddd dd Destination (00-7E, 7F:all call) 00000110 06 Machine Control Command(mcc) sub-id 00000110 06 Record strobe 11110111 F7 End Of Exclusive 5.13.1.7. MMC RECORD EXIT < Reception > This message is received if theAW16G is operating as an MMC Slave and the device number matches or is 7F. If the transport is recording, then punch-out will occur. STATUS ID No. Device ID Command EOX 11110000 F0 System Exclusive Message 01111111 7F Real Time System Exclusive 0ddddddd dd Destination (00-7E, 7F:all call) 00000110 06 Machine Control Command(mcc) sub-id 00000111 07 Record Exit 11110111 F7 End Of Exclusive 5.13.1.8. MMC RESET < Transmission > This message is transmitted with a device number of 7F when song loading is finished. < Reception > This message is received if the AW16G is operating as an MMC Slave and the device number matches or is 7F. MMC-related internal settings will be reset to the power-on state. STATUS ID No. Device ID Command EOX 11110000 F0 System Exclusive Message 01111111 7F Real Time System Exclusive 0ddddddd dd Destination (00-7E, 7F:all call) 00000110 06 Machine Control Command(mcc) sub-id 00001101 0D Reset 11110111 F7 End Of Exclusive 5.13.1.9. MMC LOCATE (TARGET) < Transmission > This message is transmitted with a device number of 7F when a locate-related key such as MARK SEARCH/IN/OUT is pressed, a FF/ REW/shuttle operation is performed, when the transport returns to the auto-punch pre-roll point, or when repeating. < Reception > This message is received if the AW16Gis operating as an MMC Slave and the device number matches. The transport will locate to the time code position specified within the command data. STATUS ID No. Device ID Command EOX 11110000 F0 System Exclusive Message 01111111 7F Real Time System Exclusive 0ddddddd dd Destination (00-7E, 7F:all call) 00000110 06 Machine Control Command(mcc) sub-id 01000100 44 Locate 00000110 06 byte count 00000001 01 "target" sub command 0hhhhhhh hh hour (Standard Time Code) 0mmmmmmm mm minute 0sssssss ss second 0fffffff ff frame 0sssssss ss sub-frame 11110111 F7 End Of Exclusive Appendix 207