Biostar VP5200SS16 Administrator Guide - Page 179
Access Control tab
View all Biostar VP5200SS16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 179 highlights
5. Customize Settings RS485 - Mode: Set the mode for a device connected via RS485 (Disable, Host, Slave, or PC Connection). - Baudrate: Set the baud rate for a device connected via RS485 (9600 to 115200). 5.1.3.4 Access Control tab The Access Control tab allows you to customize entrance limit settings and default access groups for a BioLite Net device. Entrance Limit Setting - Timed APB (min): Set the duration (in minutes) that a user will be unable to regain entry to an area via the device. Once a user has gained entry, the device will reject the user's card or fingerprint authorization for the time period specified here. - Option 1-4: Click the checkbox to enable an entrance limit setting, and then specify the effective hours for the entrance limit. - Max Number of Entrance: Set the maximum number of entries allowed during the specified time limit. Default Access Group Setting: Select a default access group to be applied to new users who have not been assigned to another access group. 179 Copyright ©2014, Suprema Inc. On the web: www.supremainc.com